background image

FF-MM-403-REV - 00

Page 3

Operation and Maintenance Guide Pneumatic Flexible Descaler TPFD75

Technical Data

IMPA Number 

Equivalent

Model No

Max. Air 

Consumption

No Load 

Speed R.P.M

Weight, Kgs

59 12 51

TPFD 75

10 cfm

5000

21

   Introduction

Teryair Pneumatic descaling machines are light and easy to handle, but rigidly constructed tools. 

They efficiently handle heavy duty scaling. Required air pressure is 0.59 Mpa (6kgf/cm²).

   Safety Instructions

Wear appropriate personal protective equip-

ments including safety goggles, foot wears, ear 

defenders facemasks & hand-gloves. 
Do not apply excessive load on the stiffeners 

while working. 
Do not store the shaft in incorrect method ot it 

gives deformation to inners. The shafts should 

be stored straight in racks with proper flat sup-

port flat support of wooden planks. 
Please check the hose connection prior to start-

ing the Pneuamtic Flexible De Scaler. 
Do not modify this equipment. 
Do keep hand & clothing away from moving 

parts. 
Do not allow the equipment to run unattended.  

Flexible De scaler should be store in dry envi-

ronment. 
These tools may cause Hand - arm vibration 

syndrome injury if there is not adequately 

managed. We advice you to carry out a risk as-

sessment and to implement measures such as; 

limiting exposure time (i.e. actual trigger time, 

not total time at work) job rotation, ensuring 

the tools are used correctly. 

  Air Supply

Tool should not be operated at air pressure 

below 5.5 Bar (80 PSI) and above 6.9 Bar (100 

PSI). 
The correct oprating pressure is 6.2 Bar(90 

PSI).

Ensure that only 3/8” (10 mm) bore airline is 

used abd all couplings are thight, leakproof and 

in good condition. The air should be clean, dry 

lubricated. Install a FRL units as close as opera-

tion will permit.

Forward

At the outset we sincerely thank you choosing 

our product. We at teryair always believe in 

offering high quality products the 
most reasonable prices. This belief has helped us 

to innovate and incorporate new ideas and thus 

enjpy a high degree of customer satisfaction.
This manual is designed keeping in mind all the 

requirements of the customer in knowing the 

prodcut its use.
This product is almost maintenance free. Only 

continous air supply at 6.33 kg/cm2 is required.

Operating Instructions

Place Pneumatic Air Motor with trolley on floor. 

Open Hose assembly (334 9728).On one of the 

ends-rotary socket has female threads. Screw on 

ths scoket on motor shaft. Tighten it fully. Then 

screw on fixing adaptor on motor end shield. 

With little force this will fit tight on motor. Then 

open Tool box and select which of these assem-

biles do you prefer to use.

Following is the guideline for    

selection

A.  For Heavy rusting - Use No.1 H.D.Tool  

 

(59 12 55)

B.  For Light rusting - Use either No.2    

 

L.G.Brush (59 12 60)

Содержание 59 12 51

Страница 1: ...TPFD 75 Read this manual carefully before installing operating or servicing this equipment It s the responsi bility of the employer to ensure this manual is read by the operator Please preserve this m...

Страница 2: ...tic Flexible Descaler TPFD75 Table of Contents 3 Introduction 3 Technical Data 3 Operating Instructions 5 Disassembly and Re assembly 6 Exploded View for TPFD 75 7 Bill of Materials for TPFD 75 8 Acce...

Страница 3: ...e i e actual trigger time not total time at work job rotation ensuring the tools are used correctly Air Supply Tool should not be operated at air pressure below 5 5 Bar 80 PSI and above 6 9 Bar 100 PS...

Страница 4: ...n it Without any as sembly screwed on the tool end till the initial vibration settles down And then screw on any selected assembly on the tool end H Recommended minimum operating radi us for the shaft...

Страница 5: ...Drive end plate 5 from Air motor 2 f Remove Tube 17 from Tube fitting elbow 11 unscrew Allen bolts 25 with Spring washers 24 from Hex nut 18 to remove Air motor 2 with Mounting plate 4 g Unscrew Tube...

Страница 6: ...FF MM 403 REV 00 Page 6 Operation and Maintenance Guide Pneumatic Flexible Descaler TPFD75 Exploded View for TPFD 75 1 3 5 11 2 4 6 7 14 10 8 9 12 13 15 16 17 18 19 20 21 22 23 24 25 26 27 28...

Страница 7: ...1 7 3424023 WHEEL 4 8 3342110 EXTENSION ROD 1 9 L12 LUBRICATOR 1 10 2009715 SILENCER 1 11 5665012 TUBE FITTING ELBOW 2 12 3342516 NIPPLE 1 13 59 12 55 CUTTER SET 1 14 3349018 GATE VALVE 1 15 3342515 A...

Страница 8: ...sc 2 4 Part No Qty Description No 2 L G Brush 59 12 60 Consists of 59 12 61 72 L G Blade 2 1 59 12 62 6 Disc Pin 2 2 59 12 63 1 2 3 Centre Bolt with Nut Washer 59 12 64 2 Disc 2 4 Part No Qty Descript...