16
-
Controller
Heat
Pump
Water temp
sensor wire
.
Swimming Pool
Pump signal wire
Pump
Drainage
Drainage
Feeding water
Figure 7 Diagram
(
Single unit for reference
)
●It is recommended to install a one-way valve for each unit to prevent water back flow.
●Multiple units can be installed as part of a system, but each unit should be controlled independently.
●All pipes and valves should be insulated.
5.2.3 Connection sizes
Model No.
Inlet
Outlet
BCPI7 BCPI10 BCPI13
BCPI17 BCPI21 BCPI30
BCPI30
DN50
DN50
●The pipe pressure and flow rate should be calculated before selecting the diameter of the pipe,
pressure drop range is 0.3
〜
0.5 kgf/cm2(3
〜
5m
)
head pipe flow rate range is 1 .2
〜
2. 5 m/s.
●The hydraulic calculation should be made after selecting the pipe diameter. If the resistance is more
than the pump head, then a more powerful pump or larger pipes are required.
5.2.4 Required Water Quality
● Bad quality water will produce more lime scale and sand: this kind of water should be filtered and
demineralize.