During leak detection and air tightness experiment, never allow oxygen, ethane or other harmful
flammable gases to enter the system: only compressed air, fluoride or refrigerant can be used for
such a test.
11.4 To remove the compressor, please do the following
●Turn off the power supply
●Remove the refrigerant from the low pressure end; make sure you reduce the exhaust speed, and
avoid leakage of frozen oil.
●Remove the compressor air suction and exhaust pipe.
●Remove the compressor power cables.
●Remove the compressor fixing screws.
●Remove the compressor.
11.5 Conduct regular maintenance according to the user manual instruction, to make sure the
unit running is in good condition.
●If there is a fire, disconnect the power immediately and put the fire out with fire extinguisher.
●The unit’s operating environment should be free of gasoline, ethyl alcohol and other flammable
materials to avoid explosions or fire.
●Malfunction: if any malfunction occurs, find the reason, fix it and then reboot he unit. Never reboot
the unit forcibly if the cause of the malfunction has not been eliminated. If there is refrigerant leakage
or frozen liquid leakage, switch the unit off. If it is not possible to turn the unit off from the controller
then disconnect the main power supply..
●Never short connect the wire for device protection otherwise, in case unit malfunction, the unit will
not be protected normally and could be damaged.
Содержание BCPI10
Страница 1: ...1 Installation Operation Manual I Full Inverter Swimming Pool Heat Pump...
Страница 26: ...26...
Страница 27: ...27 3 Key Parts Working Display Key Parts...
Страница 31: ...31 hour minute Save Adjust First Step 4 Step 3 minute Save Adjust...
Страница 43: ...43 The phone needs to be connected to the network through the WIFI network Need to select Agree...
Страница 50: ...50 Control introduction Enter the correct password and click confirm...
Страница 55: ...55 12 Fault analysis and elimination method...
Страница 56: ...56...
Страница 59: ...59...