EMERGENCY PROCEDURES
a) Isolation of the batteries on the lift is
achieved by removing a fuse. This is
located at the ramp end of the power
pack box on the platform, behind a round
blanking plug. Remove the plug to gain
access to the fuse, which can simply be
pulled out to isolate the batteries.
b) In the unlikely event that the lift stops
part-way through its travel and will not
restart, it can be lowered by removing a
round blanking cover on the top of the
power pack box on the platform and
pulling the chord, located beneath.
Please Note: If the platform is at the
upper level and will not lower, it will be
necessary to first remove the fuse as per
emergency procedure a) before following
emergency procedure b).
In the interest of safety, ensure that the
upper level gate is closed before the lift is
manually lowered.
Be aware that the platform safety device
does not function when manually lowering
the lift. Ensure that people are away
from the platform and that there are no
obstructions.
c) The Isolator switch is situated on top
of the charger pack (located indoors),
should be switched on at all times.
NOTE: A competent person will need to be
called to restore the safety functions of the lift
before re-use.