background image

SAFETY FEATURE CHECKS

As a precautionary measure it is advised that you check the 
safety features built into the lift on a weekly basis.  Carry out the 
ckecks as discribed below: -

•  Platform safe edge - With the lift at the upper level call the lift 

down and once it is moving obstruct the platform safe edge, 
the lift should stop.

•  Folding ramp upper safe edge - With the lift at lower level 

obstruct the upper surface of the ramp and send the lift up, 
the lift should stop within 300mm of travel.

•  Upper level gate - With the lift at the upper level open the 

upper level gate and attempt to call the lift down from the 
lower level. The lift should remain stationary.

All of these tests should be carried out with the lift 

unoccupied.

If any of these tests fail, the lift MUST NOT be used and advice 
sought by calling the number on the back of this booklet

12

Содержание 1100W TSL1

Страница 1: ...1100W TSL1 Platform Lift Original instructions...

Страница 2: ......

Страница 3: ...ion 4 General Do s and Don ts 6 Controls 7 Operating the Lift 8 Emergency procedures 9 Maintenance Servicing 10 Fault finding 11 Safety feature checks 12 Service history record 13 Declaration of confo...

Страница 4: ...our product gives you many years of reliable service Peter Morrey Managing Director DESCRIPTION The Terry 1100W TSL1 Lift is designed to transport a single person in a wheelchair between two floor lev...

Страница 5: ...ce If a change of use of the lift is required this should be discussed with the manufacturer supplier as certain alterations may be needed Examples of changes of use are a change of type size and or w...

Страница 6: ...the lift is kept clear from debris e g litter and leaves Do not exceed the maximum lifting capacity of 385 kg Always treat your lift with the respect that should be shown to electrical and mechanical...

Страница 7: ...ntil the lift reaches the upper or lower level Press one side of the switch to go up press the other side of the switch to go down A key switch is located on the car control panel to isolate the lift...

Страница 8: ...ress and maintain pressure on the control button to operate the lift until it stops at the required level If necessary the lift can be stopped at any time by releasing the control button The underside...

Страница 9: ...r plate below the car control panel and rotate the cover 2 Then push the lever to the left 3 to lower the lift Please Note If the platform is at the upper level and will not lower follow emergency pro...

Страница 10: ...duct If a lifting platform is to be installed in an adverse environment the specifier and supplier shall determine the measures needed to ensure that safe operations are achieved including more regula...

Страница 11: ...activated Ensure charger isolation switch is on Activate remote control enabler with key fob Lift rises short distance then stops Obstruction on ramp Remove obstruction on ramp Upper level Lift will n...

Страница 12: ...op Folding ramp upper safe edge With the lift at lower level obstruct the upper surface of the ramp and send the lift up the lift should stop within 300mm of travel Upper level gate With the lift at t...

Страница 13: ...SERVICE HISTORY RECORD An entry should be added to the following table every time the lift is serviced Date Engineer Company Comments 13...

Страница 14: ...008 Electromagnetic Compatibility Product family standard lifts escalators and moving walks Immunity BS6440 2011 Powered lifting platforms for use by disabled persons Person authorised to compile Tech...

Страница 15: ...Power supply 240V AC 50 60 Hz Control voltage 24V DC Hydraulic pump power consumption 1200W maximum Hydraulic oil grade T22 Standards Designed and manufactured to BS6440 Service interval Maximum of 1...

Страница 16: ...This 1100 W TSL1 has been supplied by 10250c...

Отзывы: