9. Operating
9.1 Initial configuration
All modules leave the factory with this control over Ethernet interface IP address: 192.168.1.10. In order to avoid conflicts
with other IP addresses, it is necessary to perform an initial configuration in the local mode. Subsequently, it will be possible
to access the module via local area network (LAN), either to change the configuration or to check the operating status.
The modules leave the factory with the following control over Ethernet interface TCP/IP configuration:
IP address of the module
:
192.168.1.10
Subnet mask
:
255.255.255.0
Default Gateway
:
192.168.1.1
To access each module, use a PC or MAC personal computer equipped with an Ethernet
card and RJ-45 cable (CAT-5E or CAT-6). The IP address of the PC/MAC must be configured
within the following range: 192.168.1.2 - 192.168.1.254 (do not use 192.168.1.10, since this
is the IP address of the module to be configured). To start the configuration of the module,
open your Web browser and type in the following direction: http://192.168.1.10. The login
prompt will appear on a screen (see Figure 6.).
Figure 6. Login prompt
Access to the Web interface is protected by user name and password. The default user name and password is
admin
.
Enter the user name and password and click on “
Login
” button.
Note
: the default password -
admin
- can (and must) be changed as explained in section
9.6.5
.
During initial configuration you need to change the default control over Ethernet interface TCP/IP configuration as explained
in section
9.4
.
The IP address of Ethernet interface reset to default value procedure is: press the "RESET" [4] button for more than 3
seconds and release it. After this operation the IP address of Ethernet interface will be set to
192.168.1.10
, user name and
password set to
admin
.
Amplifier must be fixed with 2 steel screws Ø 3.5-4 mm.
The screws are not included in a package.
³
5 cm
³
10 cm
TERRA
TERRA
³
10 cm