background image

3

1

 - 

ETHERNET

 - control over the Ethernet interface. RJ-45 socket

2

 - ACTIVITY (yellow) indicator of the Ethernet interface

3

 - LINK (green) indicator of the Ethernet interface

4

 - 

RESET

 button:

 

•  press this button shortly to restart the module

 

•  press and hold this button for more than three seconds to set the default IP address of control over the Ethernet 

 

    interface; administrator password will be changed to the default value as well

5

 - FAN connector cover plate for easy FAN replacement

6

 - power distribution bus connector

7

 - 12 V DC powering input, screw terminal

8

 - 

LASER

 - laser "

On

" safety warning LED indicator:

 

•  green light indicates that laser diode is powered on

 

•  no light indicates that laser diode is powered off

9

 - 

STATUS

 - device status LED indicator:

 

•  green light indicates that module operates normally

 

•  red light indicates device error

10

11

12

13, 14, 15, 16, 17

 - amplifier optical outputs; FC/APC socket - sources of laser radiation class 1M if output is 

                                                 opened and laser is powered

18

 - amplifier optical input; FC/APC socket

19

 - functional grounding clamp

7. Installation instructions

Read the safety instruction first.

All settings can be changed using Web browser and Ethernet interface. 

Disconnect the power supply unit from the mains before making any fiber optic cables connections.

Mount the module on DIN RAIL or individual holder.

Connect all necessary fiber optic, powering and control cables (shielded cable is recommended for Ethernet connection)

Connect power supply in to the mains.

Within 10-30 seconds of powering the amplifier will run in normal operation mode.

Comments of the Ethernet interface indicators:

• if the link with the control over Ethernet interface is established - the LINK [3] indicator glows;

• if communication via Ethernet interface is active - the ACTIVITY [2] indicator blinks.

REQUIREMENTS FOR EXTERNAL POWER SUPPLY UNIT (PSU)

• Output voltage 

+12 V 

± 

1 V

• Output current 

> 1.5 A

• Ripple at single and/or double mains frequency  < 20 mV p-p
• Ripple & noise  

< 180 mV p-p

• Output connector type 

pin (range 0.5...0.75 mm

2

)

• Short circuit protection

• Double insulated (marked 

 )

• Meet EN 55022 class B conducted emisions requirements, measuring with grounded load

Содержание OAD518

Страница 1: ...t be made by a qualified personnel Do not connect the 12 V power supply unit into the mains socket until all cables of amplifier have been correctly connected The mains socket must be easily accessible Disconnect the amplifier power supply by removing the power supply cable from the mains socket Do not expose this device to moisture or water splashes make sure no liquid filled objects e g vases ar...

Страница 2: ...vice Never leave equipment with radiating bare fibers accessible always cap the connectors 5 Cleaning of optical connectors The fiber ends may be damaged if contaminated connectors are inserted The warranty does not cover some types of damage made by the customer The standard optical connector for optical amplifier is FC APC During the operation each fiber connector may be contaminated by dust or ...

Страница 3: ...ed 18 amplifier optical input FC APC socket 19 functional grounding clamp 7 Installation instructions Read the safety instruction first All settings can be changed using Web browser and Ethernet interface Disconnect the power supply unit from the mains before making any fiber optic cables connections Mount the module on DIN RAIL or individual holder Connect all necessary fiber optic powering and c...

Страница 4: ...IN rail 8 MOUNTING The module or mounting bracket must be fixed with steel screws Ø 3 5 4 mm The screws are not included in a package Mounting on a wall by screws Mounting on a bracket supplied Perpendicular to the wall Parallel to the wall Figure 2 Mounting of the amplifier 1 2 ...

Страница 5: ...not use 192 168 1 10 since this is the IP address of the module to be configured To start the configuration of the module open your Web browser and type in the following direction http 192 168 1 10 The login prompt will appear on a screen see Figure 6 Figure 6 Login prompt Access to the Web interface is protected by user name and password The default user name and password is admin Enter the user ...

Страница 6: ... number of the device Title changeable device title Software version module software version number Hardware version module hardware version number IP IP address of the Ethernet interface System time current system time Up time time passed from last power up or restart of the module Common status table The following module parameters are displayed at real time Supply voltage module power voltage i...

Страница 7: ...P settings table MAC Address the physical address of the module Ethernet network card is displayed automatically IP Address enter the IP address that you wish to assign to the module This address must fall within the range of local network addresses Subnet mask enter the local network mask Gateway enter the IP address of the gateway This information is required only if you want to access the modul...

Страница 8: ...nity string used for generating the agent traps Host IP 1 Host IP 2 IP addresses of hosts with SNMP managers where traps will be sent Download MIB file press this link to download the SNMP MIB file of the device Save the archive on your computer and extract the archive content Extracted MIB files are ready to use with SNMP manager software NOTE please read the user guide of SNMP manager software b...

Страница 9: ...parameters window is displayed see Figure 13 Figure 13 Import parameters window Click on Click to select file and select the file containing configuration data that you wish to restore on the module Once you have selected the file click on the Upload button at the bottom of screen When the import process is finished a notification window will be displayed 9 6 4 Firmware upgrade If you wish to upda...

Страница 10: ...he user settings User role Admin enables the user to change all module settings and manage other users Limited user role User enables the password change function only It is forbidden to modify the module settings for limited user Press the Remove button to remove user from the list NOTE By giving your personal password or user access account for another person you take full responsibility for all...

Страница 11: ...PIC OPTICS CLASS 1M LASER PRODUCT Wave length 1270 1610 nm IEC60825 1 This product complies with the relevant clauses of the European Directive 2002 96 EC The unit must be recycled or discarded according to applicable local and national regulations Equipment intended for indoor usage only Functional earthing Connect to the main potential equalization This product is in accordance to following norm...

Отзывы: