50
FAULT FINDING
F
AUL
T FINDING F
AUL
T FINDING F
AUL
T FINDING F
AUL
T FINDING F
AUL
T FINDING
Installation and Servicing
67 FAULT FINDING CHART MAIN MENU
‘L1’
GO TO FRAME 68 -
FLOW TEMPERATURE OVERHEAT LOCKOUT
‘L2’
‘L6’
‘F1’
‘F2 or Fn or Ln’
‘F3’
‘L4 or F4’
‘L5 or F5’
‘F6’
‘F7’
‘F9 or L9 or F8 or L8’
‘dU’
GO TO FRAME 69 -
IGNITION LOCKOUT
GO TO FRAME 70 -
FALSE FLAME LOCKOUT
GO TO FRAME 71 -
LOW WATER PRESSURE
GO TO FRAME 72 -
FLAME LOSS
GO TO FRAME 73 -
FAN FAULT
GO TO FRAME 74 -
FLOW THERMISTOR FAULT
GO TO FRAME 75
RETURN THERMISTOR FAULT
GO TO FRAME 76
OUTSIDE SENSOR FAULT
LOW MAINS VOLTAGE -
CONTACT ELECTRICITY PROVIDER
PCB UNCONFIGURED OR FAULTY
SEE FRAME 53
IF FAULT PERSISTS REPLACE PCB
DIVERTER VALVE IN MID-POSITION FOR SERVICE
ROTATE KNOBS FULLY CLOCKWISE
TURN POWER OFF AND ON
RESTART BOILER
NO CH BUT HW OK
NO HW BUT CH OK
NO DISPLAY
GO TO FRAME 77
GO TO FRAME 78
GO TO FRAME 79
‘LC’
5 RESETS WITHIN 15 MINS -
TURN POWER OFF AND ON
RESTART PROCEDURE: to restart boiler press the restart button.
‘FU’
DIFF GREATER THAN 50°C
CHECK ISOLATION VALVES ARE OPEN
CHECK PUMP
CHECK RAD VALVES OPEN
CHECK SYSTEM BLOCKAGES