![TermoTeknik LOGIC Combi 31 Скачать руководство пользователя страница 48](http://html.mh-extra.com/html/termoteknik/logic-combi-31/logic-combi-31_installation-and-servicing_1089280048.webp)
48
SERVICING
Installation and Servicing
65 HEAT ENGINE RENEWAL
Refer also to Frame 6 - ‘Boiler Exploded View’
IMPORTANT
Before starting the removal procedure, protect the gas and electrical controls with a waterproof sheet or plastic bag.
11.
Undo the inlet pipe union nut and remove the retaining spring
clip and remove pipe.
12.
Remove the two retaining spring clips and remove the pipe.
13.
Remove the condensate rubber pipe. Refer to Frame 52, no. 2.
14.
Remove the two heat exchanger fixing screws.
15.
Remove the Heat exchanger, slide out of location bracket.
16.
If replacement sump required: Rotate heat exchanger assembly
180º. Place new sump onto heat exchanger, ensuring correct
orientation and seal is in place. Then gently apply pressure to
the base of the sump at each tab fixing point and engage tabs
onto the heat exchanger.
17.
Reassemble in reverse order, ensuring the heat exchanger LH
retaining bracket is correctly positioned. Replace any new ‘o’
rings supplied with new heat exchanger and replacing gaskets
or seals if any sign of damage is evident. When replacing the
spring clips located on the return pipe connection, ensure clip is
oriented to correctly match connecting pipe diameters.
18.
Ensure the trap/siphon is filled with water. Refer to Frame 52.
19.
Refill the boiler. Refer to Frame 24.
20.
Check operation of the boiler. Refer to Frames 31 & 32.
1.
Refer to Frame 42.
2.
Drain the boiler. Refer to Frame 55.
3.
Remove the fan / venturi assembly and place on one side.
Refer to Frame 43.
4.
Remove the burner and place on one side. Refer to Frame
45.
5.
Remove the ignition and detection electrodes. Refer to
Frames 47 and 48.
6.
Remove the spark generator. Refer to Frame 49.
7.
Remove the gas valve. Refer to Frame 50.
8.
Remove the expansion vessel. Refer to Frame 66.
9.
Remove the flow and return thermistor. Refer to Frames
46 & 64.
10.
Remove the 2 M5 screws retaining the gas valve mounting
bracket and transfer bracket to the new heat exchanger.
16
Shown as 180º position
14
11
12
10
9
9
12
SER
VICING
Содержание LOGIC Combi 31
Страница 2: ...2 Installation and Servicing ...
Страница 57: ...57 NOTES Installation and Servicing ...
Страница 58: ...58 NOTES Installation and Servicing ...
Страница 59: ...59 NOTES Installation and Servicing ...