20
burner and the bottom of the ash pit should not be lesser than 100mm - the larger
is this distance, the less often it is necessary to remove ash.
3.3. Burner pre-sets.
The burner pre-sets adjusted by the manufacturer are as follows:
- power is set to the nominal value, i.e. 15 kW, 25 kW, 40 kW and 70 kW respectively.
Modification of power parameters needs to be done by a fitter (authorized serviceman).
The user can adjust (change) power to his/her boiler by way of selecting 60% to 100%
power level throug
h settings available in the user’s menu. - all parameters have been
adjusted to the following types of fuel: type 1
– pellet ø 6 mm of average quality with
up to 1% of ash content. In case of other type of pellet (e.g. ø 8 mm or a pellet of lower
quality), it is possible to select and set parameters for fuels labelled as type 2, 3 and 4.
This should be done by an authorized serviceman.
- burner cleaning parameters are appropriate for a pellet of average ash content, i.e.
1% -
“automatic” mode and the burner is cleaned after each work cycle. It is possible
to change cleaning mode when a pellet of increased ash content is used. In such cases
it is recommended to set the “combo” cleaning mode, i.e. the mode including cyclic
cleaning during regular operation of the burner as well as the final cleaning conducted
after the work cycle ends. This should be done by an authorized serviceman.
- by default, the burner is set to central heating as well as usable warm water heating
mode of work. However, if the burner should only heat the central heating system, then
the usable warm water circuit needs to be switched off (set the usable warm water circuit
parameter into “off” mode).
3.4
Electric connection.
Make the electrical connection in accordance with the burner manufacturer's operating
instructions.
3.5
Assembling, launching and adjusting the burner
Содержание Ecomat 15
Страница 1: ...TERMOTECHNIKA OPERATION AND MAINTENANCE MANUAL FOR PELLET BURNERS ECOMAT ...
Страница 5: ......
Страница 12: ...3 2 Burner and feeder dimensions and conditions for installation in the boiler ...
Страница 13: ......
Страница 14: ......
Страница 15: ......
Страница 16: ......
Страница 17: ...Assembly hole dimensions ECOMAT100 Pellet burner ...
Страница 30: ...30 Burner serial number Burner production date Date of purchase ...
Страница 33: ...33 ...