10
goal of the two auxiliary parts of equipment (i.e. room thermostat and usable warm
water heating module) is to allow the central and usable warm water heating systems
operate at the same time. It helps to save fuel and ensures optimal operation of the
burner-boiler unit.
-
emergency stop;
The last item of auxiliary equipment for the Ecomat 15, Ecomat 25 and Ecomat 40
burners is the so-called emergency stop, i.e. a limit switch which is mounted onto
the door of a boiler which the burner was installed in. The limit switch has to be
installed in such a way to ensure that the emergency stop function is launched when
the door is opened (i.e. the burner stops operation).
Therefore, the burner can only operate when boiler’s door remain closed. It is a kind
of fire protection system which prevents from starting the burner when the door is
open. It is also helpful at removing ash from the boiler because it protects against
launching the burner accidentally during that operation. Suggested solution is
illustrated in the image below: