TMS-UT-0416-T01-0
Page 5
3. General requirements
3.1. Contents included in delivery
TermoMini boilers are delivered pre-mounted in a package unit. Make sure that all parts have
been delivered intact. For the exact list of parts, see the figure and table below. If parts are
damaged or missing, please consult our local sales office.
Figure 4 - Contents included with delivery
Table 4. Table of contents included with delivery
Item
Quantity
Description
1
1
TermoMini boiler
2
1
Instructions for installation and use
Electrical drawing
Warranty card
3
1
Hanging bracket
3.2. Preliminary remarks
When connecting the appliance to the fixing wiring, the means for disconnection (MCB) must
be incorporated in fixing wiring in accordance with the local wiring rules.
If the boiler is out of function during wintertime, there is a danger of installation freeze. In this
case, boiler should be filled with antifreeze liquid for central heating. If this is not possible
water should be drained out of the system with the help of charge and discharge valve.
Recommended pressure of central heating installation is between 0,12 MPa (1,2 bar) and
0,15 MPa (1,5 bar), maximum pressure is 0,25 MPa (2,5 bar).
3.3. Installation site
3.3.1. Position of a boiler
The location must provide adequate space for servicing and air circulation around the boiler.
The boiler can be installed in any room, although particular attention is drawn to the local
regulations in respect to the installation of a boiler in a room containing a bath or a shower.
The boiler must be mounted on a flat, vertical wall, which must be sufficiently robust to bear
the weight of the boiler. The boiler can be installed on a combustible wall, subject to the
requirements of the Local Authorities and Building Regulations.