TMS-UT-0416-T01-0
Page 9
Note:
If the boiler is to be fitted in a timber framed building, ensure that the bracket is secured to a
substantial part of the timber frame capable of bearing the weight of the boiler.
4.4. Removing/fixing the front and top case
Figure 7 - Removing front and top case
Grasp the front case by its sides, pull it towards the front and remove it by lifting it of the unit,
push top cover towards back and lift it of the unit.
4.5. Power supply connection
Note:
Before working with the appliance, turn off the power supply (MCB) and secure against
restart.
This device must be earthed.
Tightening torque for RCCB is 2,5 Nm.
Figure 8 - Power supply connection