INITIAL OPERATION OF THE DEVICE
• Ensure that the installation connections of the device are made
correctly.
• It should be sure that the air of the device and the installation
system (radiator or underfloor heating) is taken and the pressure
on the manometer should be 1.5 bar.
• Ensure that the electrical connection of the device is made cor-
rectly, that the cable is drawn in the appropriate section, that the
leakage current relay is installed in the appropriate amperes, and
that the ground line is connected. These procedures must be
done by authorized electricians.
• Ensure that the voltage supplied to the device is appropriate, low
or not high.
• The radiator temperature and external hot water tank temperature
should be set to 40 °C during the first operation of the device.
When it is operated for a while and made sure there is no air in it,
the consumer can adjust the temperature he wants.
• The device must be activated by our technical services in order
to operate efficiently and smoothly and to be valid under warranty
conditions.
Warning
The circulation pump can be locked due to calcareous water
and corrosion in devices that have not been run for 3 months
or more after water pressing. The pump should be given way.
For the devices in this case, contact the Authorized Service
must be made before starting.