Declaration of Performance
TT60-CPR-2017-Version1
Product:
Product type/application:
Room heater burning solid fuel without hot water supply
Type:
TT60:
S01-670
TT60S:
S01-672
TT60W:
S01-674
Fuel:
Wood
Productions no.
Please see nameplate on the back of the oven
Manufacturer:
TermaTech A/S
E-mail:
Gunnar Clausens Vej 36
Web:
www.termatech.com
8260 Viby J
Tel.:
+45 8742 0035
Denmark
Certification and requirements:
AVCP system:
System 3
European standard:
DS/DIN/EN 13240:2001 + A2:2004/2007
Certification:
Technologic Institute,
notified body no. 1235, has performed determination of
the
product type and declared performance on the basis of type testing and
issued test report no. 300-ELAB-2263-EN.
Declared performance:
The undersigned is responsible for the manufacturing and conformity with the declared performance.
19.10.2017
Søren Toft______________________________
Essential characteristics
Performance
Harmonised technical
specification
Reaction to fire
AI
DS/DIN/EN 13240:2001
+ A2:2004/2007
Distance to combustible materials
Rear: min. 75mm
Sides: min. 350mm
Other safety distances
–
please see User
and mounting manual
Emission of combustion products CO = 0,071%
NOx = 84 mg/m³
OGC = 62 mgC/Nm
ᶟ
PM = 8 mg/m³
Risk of burning fuel falling out
Passed
Surface temperature
Passed
Clean ability
Passed
Mechanical strength
Passed
Emission of hazardous materials
Passed
Flue gas temperature
226° Celsius
Output
6,0 KW
Energy efficiency
83 %