12.0 Safety distance and placement of the stove
The below mentioned distances are
minimum distances
to combustible materials, relevant for
this stove. These minimum distances must be respected according to the approval.
At these minimum distances the wall can still become warm,(Up to 80°C). To avoid discolorations,
smelly odor from warm paint, to maximize the heat output, and making the cleaning easier, we
recommend that you keep an distance of 80–100mm, also if the walls around the stove are of
noncombustible materials.
* Please note
, that the requirements for the fl ue pipe and chimney systems will be diff erent
from the stoves. The mentioned distances are only valid for the stove.
12.1. Safety distances to fl ammable materials using UNINSULATED fl uepipes*:
Distance to infl ammable wall behind stove: W1
100mm
Photo 1
Distance to infl ammable side wall:
W2 & W3
200/650mm
Photo 1
Distance by corner placement of 45°:
W4
225mm
Photo 2
Installation distances in front of stove:
1100mm
NOTE
: If the wall W2 (photo 1) is longer than 327mm, the distance to W1 must be extended
accordingly.
Photo 1
Photo 2
12.2. Safety distances to fl ammable materials using INSULATED fl uepipes*:
Distance to infl ammable wall behind stove: W1
75mm
Photo 1
Distance to infl ammable side wall:
W2 & W3
200/600mm
Photo 1
Distance by corner placement of 45°:
W4
200mm
Photo 2
Installation distances in front of stove:
1100mm
NOTE
: If the wall W2 (photo 1) is longer than 302mm, the distance to W1 must be extended
accordingly.
Photo 1
Photo 2