Installation of the heating element unit 

WARNING!

 The device must not be connected to electricity during installation. 

Unlug the device prior to installation.

 

1.  In case of a radiator connected to the central heating system, close both valves and 

remove the heating agent. 

2.  Insert the heating element (1) into the threaded opening in the tee piece, lockshield 

valve integrated with tee piece or directly into the radiator, depending on the 

required connection type. 

3.  Twist the head of the heating element using a spanner no 24.

4.  Position the element in such a way so that the indent in the head connection (A) was 

directed towards you or sideways. 

5.  Open the valves, fill the radiator with the heating agent from the installation and 

bleed it. 

6.  Make sure that the connection between the radiator and the heating element unit is 

tight. 

7.  Install the controller – fit the indents on the head (A) with the indents in the control-

ler (B).

 

8.  Position the controller casing in a way providing an easy and comfortable access.

WARNING! 

If you feel resistance when twisting the controller that means that you have 

reached the maximum twisting span in that direction. Try to twist the controller in the 

opposite direction. Any damage to the device will result in annulment of the warranty.

9.  Secure the casing at the back with Allen key. 

10.  Close one of the valves before using the heating element unit and leave the other one 

open (we suggest that you close the thermostatic valve). Always make sure that one 

of the valves is open prior to the use of heating element unit!!

 

11.  Connect the heating element unit to the socket/installation. The device is ready for 

use. 

Содержание KTX 1

Страница 1: ...tric Heating KTX 1 KTX 2 KTX 3 KTX 4 Gebrauchsanweisung Elektroheizpatrone KTX 1 KTX 2 KTX 3 KTX 4 Mode d emploi Kit r sistance lectrique KTX 1 KTX 2 KTX 3 KTX 4 N vod na obsluhu Topn t leso KTX 1 KTX...

Страница 2: ...not open the casing 9 Heating element s electric output cannot exceed 100 heating output of the radiator for the following parameters 75 65 20 C 10 Pressure inside the radiator must not exceed the pre...

Страница 3: ...off switch Electric supply 230 V 50 Hz Heating output available 120 200 300 400 600 800 1000 W Device protection class Class I Radiator connection G 1 2 Casing protection mark IPx4 for MS IPx5 for PB...

Страница 4: ...he below instructions 4 Other methods of correct filling of radiator can be found on www termaheat pl Radiator should not be filled with a heating agent of temperature higher than 65 C 5 Heating eleme...

Страница 5: ...troller to be flooded or wetted 13 When the level of the heating agent stops rising wait another 5 minutes turn off the heating element unit and disconnect the device from electricity 14 Do not wait u...

Страница 6: ...tion and bleed it 6 Make sure that the connection between the radiator and the heating element unit is tight 7 Install the controller fit the indents on the head A with the indents in the control ler...

Страница 7: ...24 MAINTENANCE 1 Disconnect the device from electricity prior to cleaning 2 Heating element control head should be cleaned with a dry or damp cloth with a very small amount of detergents which should...

Страница 8: ...teristics of the heating agent cause that the bottom pipes especially the two at the very bottom of the radiator may have a lower temperature than the remaining parts of the radiator this is a normal...

Страница 9: ...ile the device is on the device will turn off after 2 hours 2 TIMER Mode can also be used to TURN the device ON Turn the device off using the button press the button the device will turn on after 2 ho...

Страница 10: ...turns itself on and off periodically using only as much energy as it is required to maintain the set temperature of the radiator for current external conditions ANTI FREEZE FUNCTION When the device i...

Страница 11: ...to deactivate the Timer press the button for a while use the arrows to set the Timer to OF and press again the device will switch to the Manual Mode During the Timer operation Dryer Mode can also be...

Страница 12: ...ator icon icon indicating connection to a transmitter Heating element unit heats the radiator that it is installed in and precisely controls its temperature at the same time Buttons and are used to re...

Страница 13: ...eading Press and hold the button the display panel will show letter E followed by 4 digits separated by a hyphen actual operating time of the device ie E 0 2 1 5 means that the device was actually wor...

Страница 14: ...g signal the device will automatically return to remote operation PROBLEM SOLVING Problem Possible cause Solution Device is connected to electricity LED display panel is empty Connection problem Check...

Страница 15: ...e to incorrect not in accordance with the manual installation use or disassembly incorrect use of the heating element ie for any purpose that is not specified by the Manufacturer as intended for this...

Страница 16: ...TERMA Sp z o o Czaple 100 80 298 Gda sk Poland tel 48 58 694 05 00 fax 48 58 694 05 06 terma termagroup pl www termagroup pl MPGKE 92...

Отзывы: