MANUAL MODE 

Heating element heats the radiator that it is installed in and, at the same time, controls 

its temperature. 

For temperature regulation please use buttons   and   . LCD display panel shows current 

temperature measured inside the radiator. After settings have been modified, display 

panel will flash showing the newly set temperature for a few seconds and will go back to 

displaying current temperature. Heating indicator   will come up on the display panel if 

the newly set temperature is higher than the current one. 

In order to view the set temperature, please press any of the parameters regulation 

buttons once.

Construction of the device as well as physical characteristics of the heating agent inside 

the radiator influence the way in which the heat is distributed – the temperature of the 

bottom pipes of the radiator (especially the two located at the very bottom of the radia-

tor) may be lower than the temperature of the remaining parts of the radiator – this  

is a normal phenomenon.

Turning the device on does not mean that it uses the same maximum power for the whole 

time it is on. On turning the device on, it operates with the nominal power for a short 

period of time in order to heat up the radiator to the set temperature. After that it turns 

itself on and off periodically, using only as much energy as it is required to maintain the 

set temperature of the radiator for current external conditions.

ANTI-FREEZE FUNCTION

When the device is off and temperature around the temperature sensor drops down 

below 6°C, the device will switch on automatically. This is to prevent the heating agent 

inside the radiator from freezing. Display panel will show AF code.

DRYER MODE

Dryer mode allows to turn the device on for a certain length of time, ie. in order dry  

a towel. 

After the set length of time the device will go back to the setting from before 

the dryer mode has been activated. 

You switch the dryer on by quickly pressing   once – 

Dryer default parameters are: 

temperature of 50°C, drying time: 2 hours.

 Any subsequent quick pressing of the button 

will prolong the drying time by 0.5 hour up to 4 hours. Having reached 

4 hours, the clock goes back to the start on pressing the   button again.

Small numeric field displays exact drying time left, 

while the big one shows the same time rounded 

to a full hour.

If the device had been off before the dryer was 

activated, it will turn off automatically after the 

dryer mode is finished.

In order to interrupt the dryer mode at any time, please press  .

CLOCK 

Current time (hh:mm) is displayed both when the device is on and when it is off with an 

exception of the dryer activation time or when the device is being programmed.

time settings  

(clock/dryer/timer) –

– on/off button

– parameters regulation 

Содержание KTX 1

Страница 1: ...tric Heating KTX 1 KTX 2 KTX 3 KTX 4 Gebrauchsanweisung Elektroheizpatrone KTX 1 KTX 2 KTX 3 KTX 4 Mode d emploi Kit r sistance lectrique KTX 1 KTX 2 KTX 3 KTX 4 N vod na obsluhu Topn t leso KTX 1 KTX...

Страница 2: ...not open the casing 9 Heating element s electric output cannot exceed 100 heating output of the radiator for the following parameters 75 65 20 C 10 Pressure inside the radiator must not exceed the pre...

Страница 3: ...off switch Electric supply 230 V 50 Hz Heating output available 120 200 300 400 600 800 1000 W Device protection class Class I Radiator connection G 1 2 Casing protection mark IPx4 for MS IPx5 for PB...

Страница 4: ...he below instructions 4 Other methods of correct filling of radiator can be found on www termaheat pl Radiator should not be filled with a heating agent of temperature higher than 65 C 5 Heating eleme...

Страница 5: ...troller to be flooded or wetted 13 When the level of the heating agent stops rising wait another 5 minutes turn off the heating element unit and disconnect the device from electricity 14 Do not wait u...

Страница 6: ...tion and bleed it 6 Make sure that the connection between the radiator and the heating element unit is tight 7 Install the controller fit the indents on the head A with the indents in the control ler...

Страница 7: ...24 MAINTENANCE 1 Disconnect the device from electricity prior to cleaning 2 Heating element control head should be cleaned with a dry or damp cloth with a very small amount of detergents which should...

Страница 8: ...teristics of the heating agent cause that the bottom pipes especially the two at the very bottom of the radiator may have a lower temperature than the remaining parts of the radiator this is a normal...

Страница 9: ...ile the device is on the device will turn off after 2 hours 2 TIMER Mode can also be used to TURN the device ON Turn the device off using the button press the button the device will turn on after 2 ho...

Страница 10: ...turns itself on and off periodically using only as much energy as it is required to maintain the set temperature of the radiator for current external conditions ANTI FREEZE FUNCTION When the device i...

Страница 11: ...to deactivate the Timer press the button for a while use the arrows to set the Timer to OF and press again the device will switch to the Manual Mode During the Timer operation Dryer Mode can also be...

Страница 12: ...ator icon icon indicating connection to a transmitter Heating element unit heats the radiator that it is installed in and precisely controls its temperature at the same time Buttons and are used to re...

Страница 13: ...eading Press and hold the button the display panel will show letter E followed by 4 digits separated by a hyphen actual operating time of the device ie E 0 2 1 5 means that the device was actually wor...

Страница 14: ...g signal the device will automatically return to remote operation PROBLEM SOLVING Problem Possible cause Solution Device is connected to electricity LED display panel is empty Connection problem Check...

Страница 15: ...e to incorrect not in accordance with the manual installation use or disassembly incorrect use of the heating element ie for any purpose that is not specified by the Manufacturer as intended for this...

Страница 16: ...TERMA Sp z o o Czaple 100 80 298 Gda sk Poland tel 48 58 694 05 00 fax 48 58 694 05 06 terma termagroup pl www termagroup pl MPGKE 92...

Отзывы: