LOCAL MODE OPERATION (WITHOUT IR TRANSMITTER)

Heating mode

It is possible to set 5 temperature levels in the local mode. Settings are modified with   

and   buttons. Possible working levels are as follows: 0 (does not heat) and from 1 to 5, 

each setting indicating a temperature range from 30 to 60 degrees Celsius accordingly.   

icon indicates that the device is heating.

DRYER MODE (TIMER)

 button is used to turn the mode on and set the time after which the device is to be 

turned off automatically. 

In order to activate the Dryer Mode: 

 –  Press   button shortly – display panel will show dryer working time of 1H (1 hour) 

 –  Every subsequent pressing of the   button will prolong dryer working time (2-4 

hours)

In order to deactivate the Dryer Mode, set the time to 0H (press the   button a few 

times) or turn the device off and back on.

While the Dryer Mode is on you can modify: 

 –  temperature of the radiator – buttons   and  .

 –  Dryer working time left –   button

Actual working time meter

The unique feature measuring the actual working time of the heating element adds up 

the periods during which the device was using nominal electric power (during standard 

operation the device regulates the temperature and uses very little power thanks to the 

fact that it turns itself off for longer periods).

It can be checked at any time how much electricity has been used, ie. during all day’s 

operation. In practice it turns out to be up to a few dozens of percent less! 

The number displayed on the meter reflects the actual energy consumption, therefore 

you can measure the actual cost of energy used by multiplying the number on the meter 

by the nominal heating output of the heating element and the price of electricity (1 kW).

1.  Meter reading:  

Press and hold the   button – the display panel will show letter E followed by 4 digits 

separated by a hyphen (actual operating time of the device), ie. E..0..2..-..1..5 means 

that the device was actually working for 2 hours and 15 minutes from the last time 

the meter was zeroed.

2.  Meter resetting:  

Press and hold the   button until E 00-00 comes up. 

Setting permanent local mode

The device has been designed to work in a set, therefore, it will start searching for an IR 

transmitter signal immediately after being turned on (   icon will start flashing). If the 

device does not find an active IR transmitter, the diode will keep flashing. 

In order to turn it off, press and hold the   button until the diode stops flashing which 

will mean that the controller is no longer searching for the IR transmitter and will keep 

working in the local mode only. 

In order to go back to work with IR transmitter, press and hold the   button.

REMOTE MODE OPERATION (WITH IR TRANSMITTER) 

Controller should start searching for an IR transmitter signal immediately 

after it has been turned on – this is indicated by   icon flashing on the 

display panel. Should this not happen, press and hold the   button until 

the   icon starts flashing.

After being connected, the   zicon will stay on and a dash will appear.

When working in the remote mode, buttons   and   are not active (except when using 

the 

Dryer Mode

).

Button  : 

 –  press it short to turn the device off 

 –  press and hold to switch to the 

Local Mode

Dryer mode (timer).

Dryer in the 

Remote Mode

 is operated in exactly the same way as in the 

Local Mode

meaning that it is operated via the KTX 4 controller:

 –  press   button to activate the 

Dryer

 

 –  press   button a few times to modify 

Dryer

 operating time 

 –  press     buttons to set the required temperature level during Dryer operation (see: 

Local Mode 

operation – 

Dryer Mode

).

The controller will automatically switch to the 

Remote Mode

 on expiry of the set time.

Содержание KTX 1

Страница 1: ...tric Heating KTX 1 KTX 2 KTX 3 KTX 4 Gebrauchsanweisung Elektroheizpatrone KTX 1 KTX 2 KTX 3 KTX 4 Mode d emploi Kit r sistance lectrique KTX 1 KTX 2 KTX 3 KTX 4 N vod na obsluhu Topn t leso KTX 1 KTX...

Страница 2: ...not open the casing 9 Heating element s electric output cannot exceed 100 heating output of the radiator for the following parameters 75 65 20 C 10 Pressure inside the radiator must not exceed the pre...

Страница 3: ...off switch Electric supply 230 V 50 Hz Heating output available 120 200 300 400 600 800 1000 W Device protection class Class I Radiator connection G 1 2 Casing protection mark IPx4 for MS IPx5 for PB...

Страница 4: ...he below instructions 4 Other methods of correct filling of radiator can be found on www termaheat pl Radiator should not be filled with a heating agent of temperature higher than 65 C 5 Heating eleme...

Страница 5: ...troller to be flooded or wetted 13 When the level of the heating agent stops rising wait another 5 minutes turn off the heating element unit and disconnect the device from electricity 14 Do not wait u...

Страница 6: ...tion and bleed it 6 Make sure that the connection between the radiator and the heating element unit is tight 7 Install the controller fit the indents on the head A with the indents in the control ler...

Страница 7: ...24 MAINTENANCE 1 Disconnect the device from electricity prior to cleaning 2 Heating element control head should be cleaned with a dry or damp cloth with a very small amount of detergents which should...

Страница 8: ...teristics of the heating agent cause that the bottom pipes especially the two at the very bottom of the radiator may have a lower temperature than the remaining parts of the radiator this is a normal...

Страница 9: ...ile the device is on the device will turn off after 2 hours 2 TIMER Mode can also be used to TURN the device ON Turn the device off using the button press the button the device will turn on after 2 ho...

Страница 10: ...turns itself on and off periodically using only as much energy as it is required to maintain the set temperature of the radiator for current external conditions ANTI FREEZE FUNCTION When the device i...

Страница 11: ...to deactivate the Timer press the button for a while use the arrows to set the Timer to OF and press again the device will switch to the Manual Mode During the Timer operation Dryer Mode can also be...

Страница 12: ...ator icon icon indicating connection to a transmitter Heating element unit heats the radiator that it is installed in and precisely controls its temperature at the same time Buttons and are used to re...

Страница 13: ...eading Press and hold the button the display panel will show letter E followed by 4 digits separated by a hyphen actual operating time of the device ie E 0 2 1 5 means that the device was actually wor...

Страница 14: ...g signal the device will automatically return to remote operation PROBLEM SOLVING Problem Possible cause Solution Device is connected to electricity LED display panel is empty Connection problem Check...

Страница 15: ...e to incorrect not in accordance with the manual installation use or disassembly incorrect use of the heating element ie for any purpose that is not specified by the Manufacturer as intended for this...

Страница 16: ...TERMA Sp z o o Czaple 100 80 298 Gda sk Poland tel 48 58 694 05 00 fax 48 58 694 05 06 terma termagroup pl www termagroup pl MPGKE 92...