Document 57.4400.7200 - 1
st
Edition 03/2005
INDEX
4
16
TELELIFT 3713 Elite - 4017 - 4514
SCHEDULED MAINTENANCE PROCEDURES
A-16 CHECK THE EFFICIENCY OF THE
LIGHTING ELECTRIC SYSTEM
Check every day that the electrical system powering the
lights of the machine is in efficient working order. Use the
assistance of a second technician to check that the front
lights
A
(position lights, low and high beams and turn
signals) and the rear lights
B
(position lights, stop/tail
lights and turn signals) are in excellent state of repair.
Also check beacon
C
located on the cab roof.
If one lamp or more must be replaced, use the table
below as a reference.
A
B
C
When switched on, lamps get hot. Before touching
a lamp with your fingers, let it cool down.
Never touch the bulb of halogen lamps (mount type
H3) with your fingers: this may damage the lamp (use
of a clean cloth or a paper tissue). If you touch it
accidentally, thoroughly clean with a paper tissue
and some ethyl alcohol.
Use
Voltage
Mount type
Power
• Front low/high beam
12 V
P45t
45/40 W
• Front position lights
12 V
BA 9s
3 W
• Side/tail turn signals
12 V
BA 15s
21 W
• Stop lights and rear position lights
12 V
BAY 15d
21/5 W
• Beacon - Work lights (OPTIONAL)
12 V
H3
55 W
• Dashboard indicators and cab lighting
12 V
W 2x4,6d
1,2 W
• Interior lamp
12 V
SV 8,5-8
5 W
• License plate lights
12 V
BA 15s
5 W
• Back-up lamps
12 V
BA 15s
21W
Содержание TELELIFT 3713 Elite