ID Component ID Name
Cause
Effect
Solution
24 Pri Boom
Angle
13 Not
detected
No CAN messages
have been
received by the
TCON from the
Angle Sensor.
Machine limited to
recovery functions
* Verify sensor power P85PWR (GR,
TCON J6-7) is at 12 V while the
system is running.
* Verify the sensor is receiving power.
Unplug the sensor and verify 12 V
across pins 2 (+) and 1 (-) on the
harness connector.
* Verify the CAN bus wiring. With the
sensor still unplugged, measure
resistance across harness connector
pins 3 and 4. If resistance is not
between 55 and 65 ohms, check
CAN wire harnesses.
* Replace sensor if necessary.
14 Cross
check
failed
Boom stowed
crosscheck switch
value not as
expected
*Verify that with the boom stowed
C68LS (BL, TCON J7-3) is 12V and
that the boom is making contact with
the LST3S limit switch arm.
*Verify that with the boom above
12 degrees C68LS (BL, TCON J7-3)
is 0V and that the boom is not making
contact with the LST3S limit switch
arm.
*Check LST3S limit switch for
physical damage.
17 Not
calibrated
Sensor has been
replaced and
requires
calibration, or
calibration in
memory has been
erased.
Run the boom angle calibration
process and verify fault is no longer
active.
19 Value out
of
expected
range
Min or max boom
angle out of
expected range.
Machine limited to
recovery functions
* Calibrate boom angle snesor.
* Check boom angle sensor mount,
ensure all fasteners are tightened to
spec.
* Replace sensor if issue persists.
25 Cable
tension
21 Fault
Boom cable
tension limit switch
LSB2S indicates
that the tension is
loose on the boom
cables.
Boom Up and
Extend functions will
not operate.
* Return boom to stowed position as
quickly as possible.
* Verify both boom cables are
properly tensioned and that LST3S is
properly centered in the bracket.
* Verify LSB2S (C59CNK, BL/WH,
TCON J7-5) operates properly.
Signal should normally by 12 V. If
cable tension is loose, signal should
be 0 V.
Содержание Genie S-80 J
Страница 67: ...June 2021 Service and Repair Manual Part No 1285307GT S 80 J S 80 J TraX 55 This page intentionally left blank ...
Страница 69: ...June 2021 Service and Repair Manual Manifolds Part No 1285307GT S 80 J S 80 J TraX 57 ...
Страница 71: ...June 2021 Service and Repair Manual Manifolds Part No 1285307GT S 80 J S 80 J TraX 59 ...
Страница 78: ...Service and Repair Manual June 2021 Manifolds 66 S 80 J S 80 J TraX Part No 1285307GT ...
Страница 121: ...June 2021 Service and Repair Manual 109 Electrical Schematic Generator Options ...
Страница 123: ...June 2021 Service and Repair Manual Part No 1285307GT S 80 J S 80 J TraX 111 Electrical Schematic Positive Air Shutdown ...
Страница 124: ...Service and Repair Manual June 2021 112 Electrical Schematic Positive Air Shutdown ...
Страница 125: ...June 2021 Service and Repair Manual 113 Electrical Schematic Turntable Controller ...
Страница 128: ...Service and Repair Manual June 2021 116 Electrical Schematic Platform Controller ...
Страница 129: ...June 2021 Service and Repair Manual 117 Electrical Schematic Kubota D1803 ...
Страница 132: ...Service and Repair Manual June 2021 120 Electrical Schematic Deutz D2011 ...
Страница 133: ...June 2021 Service and Repair Manual 121 Hydraulic Schematic ...
Страница 135: ......