June 2021
Service and Repair Manual
Control System Fault Codes
Part No. 1285307GT
S
®
-80 J, S
®
-80 J TraX
™
99
ID Component ID Name
Cause
Effect
Solution
100 Platform
Level Up Coil
11 Shorted
to supply
voltage
PCON detected
that V14PLU circuit
is shorted to 12 V
or GND.
Platform Level Up
and possibly Level
Down functions will
not operate.
* With a voltmeter, measure Y20. Proper
resistance should be between 5 -
60 ohms. Replace Y20 if resistance is
outside of those values.
* Verify wiring for V14PLU (OR, PCON
J12-6) and check for open or short
circuits.
101 Platform
Level Down
Coil
11 Shorted
to supply
voltage
PCON detected
that V15PLD circuit
is shorted to 12 V
or GND.
Platform Level
Down and possibly
Level Up functions
will not operate.
* With a voltmeter, measure Y19. Proper
resistance should be between 5 -
60 ohms. Replace Y19 if resistance is
outside of those values.
* Verify wiring for V15PLD (OR/BK,
PCON J12-7) and check for open or
short circuits.
110 Platform
Rotate
Toggle
Switch @PC
27 Active at
startup
Toggle switch input
was detected as
HIGH at start-up.
Platform Rotate Left
or Right will not
operate, depending
on which side of the
switch was faulted.
*Verify with a voltmeter that the Platform
Rotate Toggle Switch (TS7) is operating
properly.
* C17PRL (GR, PCON J16-4) and
C18PRR (GR/BK, PCON J17-5) should
be 12 V when the switch is pressed in
their respective directions.
*Cycle power to allow the machine to re-
test the fault.
116 Model
Configuration
31 Setup
invalid.
Machine is not fully
configured or set to
wrong model.
Machine will not
operate.
Navigate to Settings -> Model
Configuration and ensure model,
engine, tires, and region are set and
correct.
141 Boom
10 Safety
Envelope
Exceeded
The system has
determined that
the platform
position has
exceeded the
safety envelope
boundary.
All functions will not
operate except for
the recovery
procedure.
Use Auxiliary Power and the boom
retract and/or down functions to
bring the platform back within the
operational envelope.
150 Sensor
Power
P26PWR
11 Shorted
to supply
voltage
PCON detected
that P26PWR
circuit is shorted to
12 V or GND.
Boom Up and
Extend functions
will not operate.
* Turn on machine and verify sensor
power P26PWR (BK, PCON J13-9)
is at 12 V.
* Inspect wiring for open or shorts
circuits.
152 Primary
Boom
Up/Down
Flow Coil
11 Shorted
to supply
voltage
TCON detected
that C3PBF circuit
is shorted to 12 V
or GND.
Boom Up and Down
functions will not
operate.
* With a voltmeter, measure Y12.
Proper resistance should be
between 5 - 60 ohms. Replace
Y12 if resistance is outside of those
values.
* Verify wiring for C3PBF (RD/WH,
TCON J4-4) and check for open or
short circuits.
* Verify resistance between
Recovery Module pins J37-3 and
J37-10 is zero ohms.
Содержание Genie S-80 J
Страница 67: ...June 2021 Service and Repair Manual Part No 1285307GT S 80 J S 80 J TraX 55 This page intentionally left blank ...
Страница 69: ...June 2021 Service and Repair Manual Manifolds Part No 1285307GT S 80 J S 80 J TraX 57 ...
Страница 71: ...June 2021 Service and Repair Manual Manifolds Part No 1285307GT S 80 J S 80 J TraX 59 ...
Страница 78: ...Service and Repair Manual June 2021 Manifolds 66 S 80 J S 80 J TraX Part No 1285307GT ...
Страница 121: ...June 2021 Service and Repair Manual 109 Electrical Schematic Generator Options ...
Страница 123: ...June 2021 Service and Repair Manual Part No 1285307GT S 80 J S 80 J TraX 111 Electrical Schematic Positive Air Shutdown ...
Страница 124: ...Service and Repair Manual June 2021 112 Electrical Schematic Positive Air Shutdown ...
Страница 125: ...June 2021 Service and Repair Manual 113 Electrical Schematic Turntable Controller ...
Страница 128: ...Service and Repair Manual June 2021 116 Electrical Schematic Platform Controller ...
Страница 129: ...June 2021 Service and Repair Manual 117 Electrical Schematic Kubota D1803 ...
Страница 132: ...Service and Repair Manual June 2021 120 Electrical Schematic Deutz D2011 ...
Страница 133: ...June 2021 Service and Repair Manual 121 Hydraulic Schematic ...
Страница 135: ......