June 2021
Service and Repair Manual
Control System Fault Codes
Part No. 1285307GT
S
®
-80 J, S
®
-80 J TraX
™
89
ID Component ID Name Cause
Effect
Solution
40 Jib Select
Coil
11 Shorted
to
supply
voltage
PCON detected
V18PRR is short to
supply
Jib and platform
functions will not
operate
*With a voltmeter, measure Y18.
Proper resistance should be between
5 - 60 ohms. Replace Y18 if
resistance is outside of those values.
*Verify wiring for V18PRR (GR/BK,
PCON J12-4) and check for short
circuits.
41 Turntable
Rotate
Joystick
11 Shorted
to
supply
voltage
Circuit C165TTR is
above 4.5 V.
Turntable Rotate
functions will not
operate.
* Leave joystick in neutral position
and cycle power.
* If fault persists, with a voltmeter
check that C165TTR (WH/RD, PCON
J18-2) is at 2. 5V +/- 0.2 V at startup
and does not go above 4.5 V or below
0.5 V when fully stroked in each
direction.
* Replace joystick if voltage check
fails.
27 Active
at
startup
Circuit C165TTR
voltage was not
within the startup
voltage range of 2.5
V +/- 0.2 V.
42 Turntable
Rotate CW
Coil
11 Shorted
to
supply
voltage
TCON detected that
C4TRL circuit is
shorted to 12 V or
GND.
Turntable Rotate
functions will not
operate.
* With a voltmeter, measure Y24.
Proper resistance should be between
5 - 60 ohms. Replace Y24 if
resistance is outside of those values.
* Verify wiring for C4TRL (WH, TCON
J3-12) and check for open or short
circuits.
43 Turntable
Rotate
CCW Coil
11 Shorted
to
supply
voltage
TCON detected that
C5TRR circuit is
shorted to 12 V or
GND.
Turntable Rotate
functions will not
operate.
* With a voltmeter, measure Y23.
Proper resistance should be between
5 - 60 ohms. Replace Y23 if
resistance is outside of those values.
* Verify wiring for C5TRR (WH/BK,
TCON J3-1) and check for open or
short circuits.
44 Drive
Enable
Toggle
Switch
27 Active
at
startup
Toggle switch input
was detected as
HIGH at start-up.
Drive Enable switch
will not operate,
possibly preventing
drive while the
turntable is rotated.
*Verify with a voltmeter that the Drive
Enable Toggle Switch (TS15) is
operating properly.
* C143DEL (BL/RD, PCON J16-7)
should be 0 V with the switch OFF
and 12 V with the switch held in the
ON position.
*Cycle power to allow the machine to
re-test the fault.
Содержание Genie S-80 J
Страница 67: ...June 2021 Service and Repair Manual Part No 1285307GT S 80 J S 80 J TraX 55 This page intentionally left blank ...
Страница 69: ...June 2021 Service and Repair Manual Manifolds Part No 1285307GT S 80 J S 80 J TraX 57 ...
Страница 71: ...June 2021 Service and Repair Manual Manifolds Part No 1285307GT S 80 J S 80 J TraX 59 ...
Страница 78: ...Service and Repair Manual June 2021 Manifolds 66 S 80 J S 80 J TraX Part No 1285307GT ...
Страница 121: ...June 2021 Service and Repair Manual 109 Electrical Schematic Generator Options ...
Страница 123: ...June 2021 Service and Repair Manual Part No 1285307GT S 80 J S 80 J TraX 111 Electrical Schematic Positive Air Shutdown ...
Страница 124: ...Service and Repair Manual June 2021 112 Electrical Schematic Positive Air Shutdown ...
Страница 125: ...June 2021 Service and Repair Manual 113 Electrical Schematic Turntable Controller ...
Страница 128: ...Service and Repair Manual June 2021 116 Electrical Schematic Platform Controller ...
Страница 129: ...June 2021 Service and Repair Manual 117 Electrical Schematic Kubota D1803 ...
Страница 132: ...Service and Repair Manual June 2021 120 Electrical Schematic Deutz D2011 ...
Страница 133: ...June 2021 Service and Repair Manual 121 Hydraulic Schematic ...
Страница 135: ......