First Edition • Third Printing
Operator's Manual
Inspections
Part No. 1274724GT
S
®
-40/45 XC
™
• S
®
-40/45
HF • S
®
-40/45 TRAX
™
47
74 Insert the actuator into the switch socket.
Result: The lights and horn will turn off.
75 Operate each machine function.
Result: All machine functions should operate.
a actuator
b contact alarm cable
c flashing alarm
d switch socket
Test Aircraft Protection Package
(if equipped)
Note: Two people may be required to perform this
test.
76 Move the yellow bumper at the bottom of the
platform 4 inches/10 cm in any direction.
77 Activate each function control handle or toggle
switch.
Result: No boom and steer functions should
operate.
78 Move and hold the function override switch.
79 Activate each function control handle or toggle
switch.
Result: All boom and steer functions should
operate.