Operator's Manual
Second Edition • First Printing
Work Area Safety
14 GS
™
-1330m
Part No. 1301858GT
Work Area Safety
Electrocution Hazards
This machine is not electrically insulated and will
not provide protection from contact with or
proximity to electrical current.
Obey all local and
governmental
regulations regarding
required clearance from
electrical power lines. At
a minimum, the required
clearance contained in
the chart below must be
followed.
Line Voltage
Required Clearance
0 to 50KV
10 ft
3.05 m
50 to 200KV
15 ft
4.60 m
200 to 350KV
20 ft
6.10 m
350 to 500KV
25 ft
7.62 m
500 to 750KV
35 ft
10.67 m
750 to 1000KV
45 ft
13.72 m
Allow for platform movement, electrical line sway or
sag, and beware of strong or gusty winds.
Keep away from the
machine if it contacts
energized power lines.
Personnel on the ground
or in the platform must
not touch or operate the
machine until energized
power lines are shut off.
Do not operate the machine during lightning or
storms.
Do not use the machine as a ground for welding.
Tip-over Hazards
Occupants, equipment and materials shall not
exceed the maximum platform capacity or the
maximum platform capacity of the platform
extension.
Maximum capacity
Platform extended
Model
Platform
retracted
Platform
only
Extension
only
Maximum
occupants
GS-1330m
500 lbs
227 kg
300 lbs
136 kg
200 lbs
91 kg
Indoor - 2
Outdoor - 1
Platform retracted
Platform extended
Extension only
Platform only
The weight of options and accessories, such as
panel carriers, will reduce the rated platform
capacity and must be subtracted from the platform
capacity. See the decals with the options and
accessories.
If using accessories, read, understand and obey
the decals, instructions and manuals with the
accessory.