Operator's Manual
Second Edition • First Printing
Operating Instructions
44 GS
™
-1330m
Part No. 1301858GT
Operational indicator codes
If the platform controls LED or ground controls LCD
diagnostic readout displays an operational
indicator code such as LL, the fault condition must
repaired or removed before resuming machine
operation. Push in and pull out the red Emergency
Stop button to reset the system.
LED Readout
LCD Readout
Operational Indicator Codes
Code Condition
LL Off-Level
OL Platform
Overloaded
CH Chassis
Mode
Operation
PHS Pothole
Guard
Stuck
ND
No Drive (option)
BR Manual
Brake
Release
OHL
Outdoor Height Limit
For further information, please consult the
appropriate Genie Service Manual. A code and a
description of a code can also be viewed at the
ground controls LCD display.
Platform Overload
If the platform controls LED diagnostic readout
displays a flashing OL and the ground controls
LCD diagnostic readout displays OL: Platform
Overloaded, the platform is overloaded and no
functions will operate. An alarm will sound.
1
Push in the red Emergency Stop button to the
off position.
2
Remove weight from the platform.
3
Pull out the red Emergency Stop button to the
on position.
LED Readout
LCD Readout
When the platform is being raised or lowered, a
self-check function will be performed near
maximum height. The machine may stop and an
alarm may sound. If the machine is not overloaded,
normal operation will resume.
Overload Recovery
If the ground controls LCD diagnostic readout
displays Overload Recovery, the emergency
lowering system has been used while the platform
was overloaded. For information on how to reset
the message, please consult the appropriate Genie
Service Manual.