Service Manual
March 2022
Fault Codes
88
GR
™
-20J • GR
™
-26J
Part No. 1312899GT
Error Source
Error Type
Condition
Solution
ID
Name
ID
Name
02
Controller
logic board
7
Type disparity
The controller and the base
board are not suitable for
the type of operation chosen
by the operator.
It is an internal fault. Replace the
controller.
8
HBT disparity
The HBT status is verified
by the controller and the
base board. If a difference is
found between the two, this
alarm appears.
It is an internal fault. Replace the
controller.
9
Faulty RAM
The algorithm used to verify
the main memory detects an
error. The file is corrupt.
Disconnect the key and then, if the
alarm is still present, replace the
controller.
10
Instantaneous
sum
The instantaneous sum is
different from that expected.
Incorrect software has been
downloaded or the flash
memory is corrupted.
It is an internal fault. Replace the
controller.
11
Thermal sensor
faulty
The thermal sensor is not
functioning correctly: its
output voltage is outside the
acceptable range.
It is an internal fault. Replace the
controller.
12
Stand by motor
right
The right armature current
sensor detects a current
other than zero when the
right motor is not running.
It is an internal fault. Replace the
controller.
13
Stand by motor
left
The left armature current
sensor detects a current
other than zero when the left
motor is not running.
It is an internal fault. Replace the
controller.
14
High field
current
A current other than zero
passes through the field
circuit even if the field
conductor is not active.
It is an internal fault. Replace the
controller.
15
Analog input
There is a fault in the A/D
converter of the
microcontroller.
It is an internal fault. Replace the
controller.
16
Trac. I sensor
The current sensor for the
armature of motor 1 and/or
motor 2 is not functioning
correctly: its output voltage
is outside the acceptable
range.
It is an internal fault. Replace the
controller.
Содержание Genie GR-20J
Страница 12: ...Service Manual March 2022 xii GR 20J GR 26J Part No 1312899GT This page intentionally left blank ...
Страница 25: ...March 2022 Service Manual Part No 1312899GT GR 20J GR 26J 13 This page intentionally left blank ...
Страница 77: ...March 2022 Service Manual Function Manifold Part No 1312899GT GR 20J GR 26J 65 ...
Страница 113: ...March 2022 Service Manual 101 Electrica l Schemati cs Electrical Schematic GRJ from GRJL 2298 ...
Страница 116: ...Service Manual March 2022 104 Electrical Schematic GRJ from GRJL 2298 ...
Страница 117: ...March 2022 Service Manual 105 GCON LED Panel GRJ from GRJL 2298 ...
Страница 120: ...Service Manual March 2022 108 Temperature Sensor Harness GRJ from GRJL 2298 ...
Страница 121: ...March 2022 Service Manual 109 Options GRJ from GRJL 2298 ...
Страница 123: ...March 2022 Service Manual 111 Hydraulic Sc hema tics Hydraulic Schematic 2 2 kw from GRJL 2298 ...
Страница 127: ......