3-5
3.5 Precautions for wiring work
Danger
Use high-quality wiring equipment and devices, and carry out wiring work
safely and securely according to the technical standards for electrical
facilities, as well as the indoor wiring regulations.
Only qualified personnel such as licensed electrical engineers are allowed
to carry out electrical wiring work. Unqualified persons are prohibited by
law to carry out wiring work, and it is very dangerous.
Danger
Securely connect the terminals of the power cable. Loose terminals may
cause the motor to run in open-phase condition, thus leading to motor
burnout.
(1) For the size of the power cable, refer to the following:
Model
Minimum size of the cable
All models
1.6 mm
2
(2) Be sure to install a ground fault interrupter and an overload protection device on the primary
power side of the pump.
(3) Securely connect to the power by wiring the terminals according to the right figure.
* If there are four or more terminals, follow the connection nameplate in the terminal box.
No.
Item
Qty
Material
Note
1 Screw
6
SS
M4
2 Screw
1
SUS
M4
3 Terminal box lid
1
SPCE
t=1.2
4 Terminal box packing
1
NBR
t=1.5
5 Screw
4
SS
M4
6 Terminal box case
1
SPCE
t=1.2
7 Terminal box seat
1
ADC12
8 Packing
2
Corkprene
9 Screw
2
SS
M5
(4) Be sure to attach a ground wire to prevent an electric shock. Connect the ground wire to the
ground terminal inside the terminal box of the motor.
Terminal box layout drawing
Terminal box detail drawing
Electrical schematic
CR