background image

 

A S T   3 9 8 8 0   ( 0 8 0 7 )  

2 2   o f   3 0  

 

6 . 3   C o n t r o l   U n i t / M o d u l e   U p d a t e   i n   S t o r a g e   M o d e  

NOTE: 

  Storage Mode works similar to Pass-thru Mode. You will see the same CM Update 

software screens during the vehicle system selection. To complete a Storage Mode 
update at the vehicle, you need the Trigger Switch Adapter Block (TDS3554 1434) 
and the Trigger Switch (TDS35541 359). 

  These instructions are a summary of the updating process. 

  For a description of the GNA600 Kit parts used in this procedure, refer to section 3.3. 

1.  Connect the USB PC Interface Cable to the 

i

N Workstation and to the GNA600. From the 

Updating Honda Control Modules 

main screen, select 

Storage Mode 

and follow the 

on-screen instructions. 

2.  Connect the DLC Cable to the GNA600 and to the vehicle’s DLC. (You don’t need to turn 

the ignition switch to ON (II) before connecting the GNA600. This applies only to the HIM.) 

3.  Turn the ignition switch to ON (II), and wait until the green #2 LED on 

the GNA600 stays on. Turn the ignition switch off, and disconnect the 
DLC Cable from the vehicle. 

 

4. Connect the USB PC Interface Cable to the 

i

N Workstation and to 

the GNA600. Connect the Power Supply Unit and Power Supply 
Cord to the GNA600. The GNA600 will start a self-check. After 
about 30 seconds, the GNA600 LEDs flash green and yellow.

 

5.  Select the vehicle system that you are updating, then click on the 

Check Mark 

on the right 

side of the screen. 

 

Содержание GNA600

Страница 1: ...CE USER GUIDE FOR HONDA VEHICLES 2008 American Honda Motor Co Inc All Rights Reserved AST 39880 0807 www autocardiag com E mail autocardiag gmail com Skype Marshall obd2 Whatsapp 86 13476108995 w w w...

Страница 2: ...oftware 11 5 SETUP 12 5 1 Before You Start 12 5 2 Setup Basics 12 5 3 Connection With the USB PC Interface Cable 13 5 4 Connection With an Ethernet Cable 13 6 UPDATING CONTROL UNITS MODULES 15 6 1 Ove...

Страница 3: ...C to be useful How to Resolve Radio TV Interference Problems This booklet is available from the U S Government Printing Office Washington DC 20402 Stock 004 000 00345 4 1 2 Use of This Equipment in Ca...

Страница 4: ...overheat Take care to arrange the cord so that it will not be tripped over or pulled accidentally 7 Always unplug the equipment from the electrical outlet when not in use Never use the cord to pull t...

Страница 5: ...maintenance and cleaning operations refer to the Care and Maintenance section Use only a well diluted mild non abrasive cleaning agent applied by using a soft lint free cloth DO NOT allow the GNA600...

Страница 6: ...the functions of the HIM Honda Interface Module but with additional capabilities The GNA600 is easiest to use with a wired USB connection but it can also be used with an Ethernet connection Here are t...

Страница 7: ...Unit 5 Power Supply Cord 6 Trigger Switch Adapter Block Yellow 7 PC Interface Adapter Block Blue 8 Trigger Switch 9 256 MB PCMCIA Memory Card These are optional parts that can be purchased separately...

Страница 8: ...splay diagnostic data on the PC screen DLC Cable TDS35541 433 Connects the GNA600 to the vehicle s 16 pin DLC Power Supply Unit TDS6067801 0 Provides A C power to the GNA600 when it is not connected t...

Страница 9: ...gger Switch TDS35541 359 When it is connected to the Trigger Switch Adapter Block TDS35541434 the Trigger Switch allows the GNA600 to update control units modules in Storage Mode without a PC Not all...

Страница 10: ...th the HDS software package and can be installed according to the instructions provided by the software distributor The GNA600 can be used with both HDS software and Control Module CM Update software...

Страница 11: ...0 This does not indicate a connection to a vehicle The GNA600 can be selected as the default vehicle interface during installation of the HDS software or from the setup screen After you select the GNA...

Страница 12: ...d as the default vehicle interface during installation of the Control Module CM Update software or from the setup screen The LED patterns seen on various screens during use of the CM Update software s...

Страница 13: ...fully automatic if you have the correct drivers from the HDS software installed use the USB PC Interface Cable and carefully follow the set up instructions If you use an Ethernet cable you must do a m...

Страница 14: ...ble To use an Ethernet connection you must configure the network adapter on the PC to a static address and use a straight through Ethernet cable not supplied You must also connect the PC Interface Ada...

Страница 15: ...2 16 0 1 with a subnet mask of 255 255 255 0 Use an address that does not conflict with other network settings on that PC No gateway or DNS settings are required Once the address is set restart the PC...

Страница 16: ...n enhanced to show the progress during the update as well as showing on screen instructions and the LED patterns you will see on the GNA600 The CM Update software can be used in Pass thru Mode or Stor...

Страница 17: ...hown to the right the CM Update software is launched from the Windows Start menu To do control unit module updates the latest HDS software must be installed see section 4 A S T 3 9 8 8 0 0 8 0 7 16 of...

Страница 18: ...GNA600 LED patterns see section 7 3 1 Connect the USB PC Interface Cable to the iN Workstation and to the GNA600 From the Updating Honda Control Modules main screen select Pass thru Mode 2 Connect th...

Страница 19: ...0 4 Select the vehicle system that you are updating then click the Check Mark on the right side of the screen 5 Verify that the Program ID and the Program Part No are for the system you selected in st...

Страница 20: ...pdate by Program ID and Program Part No Make sure this corresponds with any information provided in the service bulletin for the update you are doing Click on Yes to continue The CM Update software lo...

Страница 21: ...8 0 0 8 0 7 2 0 o f 3 0 7 Click on the Check Mark to begin the control unit module update NOTE On non CAN vehicles the update can take 15 to 30 minutes CAUTION To avoid ECM PCM damage do not interrupt...

Страница 22: ...completed turn the ignition switch to LOCK 0 and then back to ON II within 60 seconds 9 Once the software verifies that the control unit module has been successfully updated click on Yes to update an...

Страница 23: ...pdating Honda Control Modules main screen select Storage Mode and follow the on screen instructions 2 Connect the DLC Cable to the GNA600 and to the vehicle s DLC You don t need to turn the ignition s...

Страница 24: ...eck Mark 7 Confirm the control module update by Program ID and Program Part No Make sure this corresponds with any information provided in the service bulletin for the update you are doing Click on Ye...

Страница 25: ...h button 11 The yellow 1 LED blinks and the green 2 LED stays on This indicates that the control unit module is being updated NOTE On non CAN vehicles the update can take 15 to 30 minutes CAUTION To a...

Страница 26: ...setup details are correct 6 Reboot the computer and restart the software 7 Completely disconnect the GNA600 from the computer the vehicle and power supply and reconnect according to section 5 2 7 2 C...

Страница 27: ...from the control unit module OFF ON OFF Ready for updating BLINKS ON OFF Updating is in progress ON OFF OFF The control unit module has been updated Turn off the ignition switch BLINKS OFF OFF The ign...

Страница 28: ...cleaners or any type of polish If dust or other particles get on the GNA600 Unit lightly brush the unit off with a soft lint free cloth 8 2 Cable Care Always return the cables to their appropriate sto...

Страница 29: ...t 15 to 85 RH non condensing Storage 20 C to 70 C 4 F to 158 F at 15 to 85 RH non condensing Standards and Regulatory The GNA600 fulfills the requirements of the CE marking Compliances scheme and UL20...

Страница 30: ...ions in any software used with the GNA600 relating to required cable connections Failure to follow these instructions can result in permanent damage to the GNA600 Such damage is not covered by this wa...

Страница 31: ...ed or otherwise regarding the accuracy and completeness of this document and shall in no event be liable for any loss of profit or any other commercial damage including but not limited to special inci...

Отзывы: