3.4.13
Menu: Comport / Settings
The ‘comport / settings’ webpage defines the parameters for the ENC's integrated comport/serial port.
ENC-
300™ encoders are always comport servers and DEC-200 decoders are always comport clients.
Figure 26: 'Comport / Settings' page of the ENC-
300™ encoder
Settings:
Description:
Mode:
Specifies the comport mode.
‘Console’
enables access and control of the ENC-
300™
configuration via the com-cable (null modem cable). Use this
cable to set the ENC-
300™ configuration when you do not want
to use web access.
‘Passthrough’
enables setting the comport to a serial mode. RS-
232 devices can be connected and controlled via the comport.
This is useful, for example when cameras or other non-IP, non-
network devices need to be remotely controlled. RS-232
commands can be tunnelled and sent via TCP/IP to the comport
server, where they will be returned into native RS-232
commands. When a connection is opened from the client (e.g.
decoder) to the IP-address of the encoder at port 7777, the serial
function in the ENC-
300™ is activated and any data (string) is
passed straight to the connected RS-232 device. Once the
connection is established, this also works the other way for
information coming back from the RS-232 device.
Bitrate:
Specifies the used bitrate in bits per second.
Databits:
Specifies the databits. You can choose between ‘7’ and ‘8’. This
field is only available when the comport mode ‘Passthrough’ is
chosen.
Parity:
Specifies the parity. You can choose between ‘none’, ‘odd’ and
‘even’. This field is only available when the comport mode
‘Passthrough’ is chosen.
Stopbits:
Specifies
the value of used stopbits. You can choose between ‘1’
and ‘2’. This field is only available when the comport mode
‘Passthrough’ is chosen.
Table 23: Description of the 'COMPORT/SETTINGS' webpage of the ENC-
300™