![TeraBee TeraRanger Evo Swipe Plus Скачать руководство пользователя страница 29](http://html1.mh-extra.com/html/terabee/teraranger-evo-swipe-plus/teraranger-evo-swipe-plus_user-manual_1088208029.webp)
6. General Remarks
●
If the sensor is disconnected/powered down, the BPTD or PD counters are
automatically reset.
●
The parameter sliders present in the GUI are connected to each other. For
instance, if you move the maximum range value for the Swipe Mode too close
(<25 cm) to the minimum range threshold of the Engagement Trigger Mode, then
this Engagement threshold will automatically increase to keep the minimum
range interval required.
●
Once a validation gesture has been detected, a left/right movement may be
detected immediately after, if the person’s hand is properly aligned with the
sensor. In this case, we suggest:
○
Increase the gap between the respective thresholds of the Validation and
Swipe mode, in order to filter unwanted Swipe detection.
○
Set a timer of 0.5 seconds after a Validation event, in order to not
acknowledge the following movement (hand exiting a validation status).
Copyright
©
Terabee 2020
Terabee, 90 Rue Henri Fabre
01630, St Genis-Pouilly, France (next to CERN)