5. Ready for operations
Once the autotest mode has ended, the device will enter the battery saving mode (SLEEP
MODE), until it will be automatically powered again for measurements and LoRa data
transmissions based on pre-configured intervals.
Before further device installation, please screw back & lock the upper device lid to ensure
IP65 protection to inner electronic components. Make sure that the antenna connection is
tight (no free movements).
Default device parameters
Terabee device comes pre-configured with default network and applications parameters.
The following list provides an overview of these parameters, configured during the
production process.
Activation method :
OTAA
Device EUI :
provided, unique to each device
Application EUI :
-
Application Key :
provided, random to each device
Radio Frequency (LoRa) :
EU868 MHz; US915 MHz
Adaptive Data Rate (ADR) :
Enabled
Spreading Factor :
-
Uplink Confirmation :
Disabled
Measurement and Transmission Interval : 1 reading / 1 hour
Level Estimation :
Disabled
When using the Terabee Configuration GUI with the Terabee device, the software auto-fills
the codes in the DevEUI and AppKey parameter fields.
Device EUI (DevEUI) and Application Key (AppKey) codes for each device can be also found
embedded in a QR code that is printed on a label - located on the inner side of the TOP lid.
Example is presented below.