![TERABEAM Marquee P-MP Series Скачать руководство пользователя страница 17](http://html1.mh-extra.com/html/terabeam/marquee-p-mp-series/marquee-p-mp-series_user-manual_1088183017.webp)
Marquee™ Point-to-MultiPoint Series User Guide
7. Repeat steps 7 and 8 above to guarantee optimum alignment for maximum signal strength.
CAUTION:
It is possible to obtain a false peak SNR reading from the signal of a side-lobe. Up to three
different side-lobes on either side of the main lobe may give false peak alignment readings.
For this reason, it is important that a wide sweep in both azimuth and elevation is made in
order to identify these false peak SNR readings so to zero in on the true peak alignment
reading due to the main antenna beam.
8. Tighten the two Azimuth adjustment bolts while observing the SNR reading to ensure the azimuth
alignment does not change while tightening.
9. Tighten the Elevation adjustment bolt while observing the SNR reading to ensure the elevation
alignment does not change while tightening.
10.
Test the Link
. Prior to placing the link in service for network traffic, the link should be tested using
standard network procedures.
Version 1.3(a)
Page 14
Jul 2005