4. TIP
4. TYPE
TIP / TYPE
P [W]
IZVOR / LAMP
TYPE
Un [V]
Ø [lm]
GRLO / LAMP
HOLDER
In [A]
MASA /
WEIGHT
PSF 218
2 x 18
T8
230
2 x 1350
G13
0,17
7,5 kg
PSF 236
2 x 36
2 x 3350
0,33
10 kg
PSF 258
2 x 58
2 x 5200
0,5
12 kg
TIP / TYPE
P [W]
MAIN
IZVOR /
LAMP TYPE
Un [V]
Ø [lm]
GRLO / LAMP
HOLDER
In [A]
MASA /
WEIGHT
MAIN
EM. 1,5h
EM. 3h
PSF 218E
2 x 18
T8
230
2 x 1350
1 x 800
1 x 550
G13
0,17 A
9 kg
PSF 236E
2 x 36
2 x 3350
1 x 2000
1 x 1000
0,33 A
12,5 kg
5. POLARNA KARAKTERISTIKA
5. POLAR CURVE
6. MONTAŽA I INSTALACIJA
6. MOUNTING AND INSTALLATION
Svjetiljka se standardno isporučuje sa fluorescentnim cijevima, sa
dvije Ex eb uvodnice M25 (za kabel 7-15mm), tri Ex eb čepa M25 te
priborom za ovjesnu montažu (PSF 30-150).
Svjetiljka je namijenjena za vanjsku i unutarnju primjenu.
Napomene za sigurnu instalaciju i montažu:
Provjera temperature okoline
Mogućnost instalacije u zonama opasnosti 1, 2, 21, 22
Provjera mjesta ulaza kabela u svjetiljku (narušena
mehanička zaštita, IP broj)
Oštećenje svjetiljke narušava protueksplozijsku zaštitu
prostora u koji je instalirana!
Otvaranje i zatvaranje svjetiljke:
Skinuti gumenu zaštitu sa centralne blokadne
sklopke. Okrenuti centralnu osovinu 180
0
ulijevo (natpisna pločica - OPEN), s nasadnim
ključem. Klizači oslobađaju transparentni
pokrov i svjetiljka se otvara. Prilikom zatvaranja
slijediti obrnuti redoslijed radnji.
Prilikom zatvaranja svjetiljke, obratiti pažnju
na pozicioniranje brtve (utor u pokrovu) u
odnosu na kućište.
Fluorescent lighting fitting comes standard with fluorescent tubes, two
Ex eb cable glands M25 (for cable 7-15mm), three Ex eb plug M25 and
accessories for suspension assembly (PSF 30-150).
The lamp is designed for indoor and outdoor use
.
Notes for safe installation and assembly:
Check the ambient temperature
Possibility of installation in hazardous areas 1, 2, 21, 22
Checking of cable entry into the fluorescent lighting fitting
(compromised mechanical protection, IP number)
Damage lamps does not ensures explosion protection of
the area in which lamp is installed!
Opening and closing of the fluorescent light fitting:
Remove the rubber protection on the central
interlocking switch. Turn the central axis 180° to the
left (marking - OPEN) with a socket wrench. Sliders
release transparent cover and the lamp opens. When
closing follow the orders of operations in reverse.
When closing, pay special attention to the
positioning of the seal (slot in the cover) relative to