TENSITRON STX-1 Series Скачать руководство пользователя страница 12

       STX-1 Series Instrument           

www.tensitron.com                      

pg. 12

 

 

 

o

 

Version 

Press this button to determine what Model the instrument is set at in the 
firmware as well as to see what level of firmware is downloaded to the 
Instrument. 

 

DATA LOGGING Screen 

Each time the instrument’s STORE button is pressed, a log of that strap tension 
will be stored into memory for later review.  

o

 

View Data Stats 

This feature allows the operator to view the basis statistics of the 
logged data (Count, Average, Minimum/Maximum, and Standard 
Deviation).  

o

 

View Data Log 

When data is logged to the instrument memory, that data and the 
statistics of that data log (Count, Average, Minimum/Maximum, and 
Standard Deviation) can be seen under the Data Logging / View Data 
Stats screen. To view this logged data: 

 

Scroll to DATA LOGGING and press ENTER. 

 

Scroll to VIEW DATA LOG and press ENTER. 

o

 

Clear Single Point Log 

To clear stored data, scroll to CLEAR SINGLE PT LOG, press ENTER, 
and follow the prompts. 

 

 

TENSION UNITS Screen 

To change the unit of measure in which tension readings are logged: 

 

Scroll to Tension Units and press ENTER. 

 

Use the Up and Down arrows to select Kilograms, 
DecaNewtons or Pounds and press ENTER. 

 

SELECT MATERIAL Screen 

Press ENTER while this display is shown to show the available options for the 
material types. Use the up or down arrow to scroll to the option you want and 
press ENTER to select it. 

Set Point Setup Screen 
 
See High and Low threshold values 
Settings: 

On / Off 
Edit High Point Threshold 
Edit High Point Threshold 

Figure 6: Setpoint Setup

 

Содержание STX-1 Series

Страница 1: ...STX 1 Series Instrument www tensitron com pg 1 Operating Instructions STX 1 Series Digital Strap Tension Meter...

Страница 2: ...2 Serial Output option 6 Features of all Instruments 7 5 BASIC OPERATION 8 Charging Instrument Batteries 8 Quick Start Instructions 8 Engaging Instrument onto Strap 10 6 DISPLAY SCREENS 10 SETUP Scree...

Страница 3: ...stions or need assistance please call us at 303 702 1980 or find us online at www tensitron com 1 WARRANTY POLICY STANDARD EQUIPMENT WARRANTY Tensitron warrants that all Tensitron manufactured equipme...

Страница 4: ...and PET strappings Power Requirements For Instrument Input 9 VDC 2 2A For AC Adapter 100 240V 50 60Hz 0 48A Power Supply operates with input voltages from 100 240V and includes several interchangeabl...

Страница 5: ...nstrument to do a job for which it is not recommended Check for damaged parts Inspect instrument before use Check for any binding of moving parts improper mountings broken parts and any other conditio...

Страница 6: ...nstruments include multiple selections for different strapping Models STXM 250 1 through STXM 1000 1 includes multiple selections for Poly and PET strappings The Model STXM 2000 1 includes selections...

Страница 7: ...calibrations can be programmed into the instrument Password protected to provide due diligence against unauthorized changes Adjustable LCD refresh rates allow for stable digital readings Automatic shu...

Страница 8: ...and corner of display Quick Start Instructions 1 Power unit on by pressing ON button Main display will indicate Tension Material Min and Max readings and other information See Figure 3 2 Select a scre...

Страница 9: ...n press ENTER b Next select from Kilograms DecaNewtons or LBS and then press ENTER 6 Select Material a Using the up or down arrows scroll to SELECT MATERIAL then press ENTER b Next scroll through the...

Страница 10: ...LCD refresh rates Scroll to SETUP and press ENTER Scroll to LCD REFRESH RATE and press ENTER Select your preference 1 2 or 5 Hz and press ENTER Note This feature is unrelated to Data Averaging o Data...

Страница 11: ...CHECK ACCURACY o Audio To turn the Beep ON or OFF Scroll to SETUP and press ENTER Scroll to AUDIO and press ENTER Select ON or OFF and press ENTER o Backlight To adjust the visual intensity of the LC...

Страница 12: ...ndard Deviation can be seen under the Data Logging View Data Stats screen To view this logged data Scroll to DATA LOGGING and press ENTER Scroll to VIEW DATA LOG and press ENTER o Clear Single Point L...

Страница 13: ...by holding it in the same attitude you ll be taking the readings and press the Enter or Zero button This will eliminate any small tare effects 3 Take readings along the strap FOR BEST RESULTS ALWAYS...

Страница 14: ...for it by following the instructions under Custom Names in Section 6 above 1 Scroll to SETUP and press ENTER Next scroll to RE CAL TENSION and press ENTER The screen will now display SETUP RE CALIBRAT...

Страница 15: ...m above and suspend known weights onto the strap in the values you ve previously selected when prompted See Figure 7 a CALIBRATE TENSION NUMBER OF POINTS __ ZERO UNIT Without any strap engaged to the...

Страница 16: ...733 S Bowen Street Longmont CO 80501 USA Phone 303 702 1980 Fax 303 702 1982 E mail sales tensitron com Web Site www tensitron com...

Отзывы: