STX-1 Series Instrument
www.tensitron.com
pg. 12
o
Version
Press this button to determine what Model the instrument is set at in the
firmware as well as to see what level of firmware is downloaded to the
Instrument.
•
DATA LOGGING Screen
Each time the instrument’s STORE button is pressed, a log of that strap tension
will be stored into memory for later review.
o
View Data Stats
This feature allows the operator to view the basis statistics of the
logged data (Count, Average, Minimum/Maximum, and Standard
Deviation).
o
View Data Log
When data is logged to the instrument memory, that data and the
statistics of that data log (Count, Average, Minimum/Maximum, and
Standard Deviation) can be seen under the Data Logging / View Data
Stats screen. To view this logged data:
▪
Scroll to DATA LOGGING and press ENTER.
▪
Scroll to VIEW DATA LOG and press ENTER.
o
Clear Single Point Log
To clear stored data, scroll to CLEAR SINGLE PT LOG, press ENTER,
and follow the prompts.
•
TENSION UNITS Screen
To change the unit of measure in which tension readings are logged:
▪
Scroll to Tension Units and press ENTER.
▪
Use the Up and Down arrows to select Kilograms,
DecaNewtons or Pounds and press ENTER.
•
SELECT MATERIAL Screen
Press ENTER while this display is shown to show the available options for the
material types. Use the up or down arrow to scroll to the option you want and
press ENTER to select it.
Set Point Setup Screen
See High and Low threshold values
Settings:
On / Off
Edit High Point Threshold
Edit High Point Threshold
Figure 6: Setpoint Setup