Sec. 2.  CHARGING INSTRUMENT BATTERIES.  

 
1.  Connect power supply cable to instrument. 
2.  Plug the power supply into a 100 – 240 VAC outlet. 
3.  Fully charge battery prior to first use (approximately eight hours).  
4.  Battery pack assembly cannot be overcharged, however instrument will 

remain on while plugged into power supply. 

5.  Fully charged battery assemblies will operate approximately six hours  

+/- 20% depending upon usage and backlighting intensity. 

6.  Battery charge level is indicated in the upper, right-hand corner of 

display. 

 

Sec. 3.  OPERATION:  

QUICK START

 
1. 

TURN UNIT ON 

by pressing 

ON

 button.  Display shows: 

Tension

 (LBS, 

Newtons, or Kilograms), 

Cable 

size selected and battery charge level. 

2. 

MEMORY FUNCTION.

  Depress the 

MEMORY 

button to store and 

display up to five separate tension readings, plus the average (

AVG

) of 

these stored values. 

3. 

MOVE BETWEEN SCREENS 

by pressing either the 

 

or 

 

arrows. To 

make, or enter a selection, depress the 

ENTER 

key.  To exit a setting, 

depress the 

ESCAPE 

key.  

4. 

ZERO THE INSTRUMENT 

before taking readings by holding the 

instrument in the attitude in which it will be used, and with no load 
applied press the button marked 

ZERO

5. 

READING OF TENSION.  

Variations in materials and sizes affect 

tension readings. It is essential to select the correct material and size 
from the calibration menu before use , or values may be incorrect. 

6. 

SELECT MATERIAL.  

From the Main Display (first screen seen when 

unit is turned on) use the 

 

or 

 

keys until 

SELECT MATERIAL 

is 

displayed.  Press 

ENTER

.  Next toggle through the various selections 

using the 

 

or 

 arrows until correct cable size is highlighted, and press 

ENTER

 to make your selection.  

If your specific material is not listed, 

follow the calibration instructions included at the end of these 
instructions, or send a sample and the instrument to Tensitron for a 
custom calibration.

  

7. 

SELECTING TENSION UNITS IN lb, kg or daN.  

Press the 

 

or 

 

keys 

until 

TENSION UNITS 

is displayed.  Press 

ENTER

.  Next, select:  

LBS

Kilograms 

or 

Decanewtons 

and 

ENTER 

selection. 

8.   

ENGAGE INSTRUMENT TO TENSIONED MATERIAL.  

For best 

accuracy hold the instrument in the attitude the measurement will be 
taken in and press 

ZERO

.  Push “closure bar” away from the instrument 

handle to raise the outer cable guides.  Engage the tensioned material 
by routing the cable so that it falls under the outer cable guides and over 
the center, contact point.  Squeeze the “closure bar” shut until it locks 
into position beside the handle, and note the tension reading.  (See 
photo on Page 14.)

 

Page 2     ACX-Series Operating Instructions 

 
 

Verify the tension value.  For example, if your suspended 
weight is 41.0 lb your instrument should also indicate 41.0 lb 
+/- 5.0 lb once properly engaged to the cable.  This procedure 
confirms the instrument’s accuracy and it is now ready for use.   

 
 

Note:  

Full-scale accuracy is +/- 2% for all menu selectable 

calibrations.  Accuracy for custom calibrations is material spe-
cific.    
 
For an instrument with a full-scale range of 250 lb this trans-
lates into +/- 5.0 lb, and for an instrument with a full-scale 
range of 500 lb, accuracy is +/- 10.0 lb. 

 

 

* Should you have additional questions, please contact  

 

Tensitron to speak with an applications engineer.  

 

 
 

                                           ACX-Series Operating Instructions  Page 15     

Содержание ACX-Series

Страница 1: ...C 733 S Bowen Street Longmont CO 80501 USA Phone 303 702 1980 Fax 303 702 1982 E mail tensionmeters tensitron com Web Site www tensitron com Operating Instructions ACX Series Digital Aircraft Cable Te...

Страница 2: ...s for calibration take a sample length of your material and suspend it from above See Page 12 Fig 1 Next hang weights from your material in the weight values you previously selected in enter weights 1...

Страница 3: ...manual carefully to learn your tension meter s applications and limitations as well as the potential hazards associated with this type of instrument 2 AVOID DANGEROUS ENVIRONMENTS Do not use your inst...

Страница 4: ...oggle through the various selections using the or arrows until correct cable size is highlighted and press ENTER to make your selection If your specific material is not listed follow the calibration i...

Страница 5: ...REFRESH RATES DAMPENING ADJUSTMENT To either speed up or slow down the rate at which tension values refresh on the display use the or keys select SETUP and press ENTER Next select Dampening and after...

Страница 6: ...ext using the and arrows select ANALOG OUTPUT Press ENTER Using the and arrows select from ANALOG TENSION CURRENT or ANALOG TENSION VOLTAGE Once correct selection is made press ENTER 9 CALIBRATION OF...

Страница 7: ...units output serially will be the same units that are selected in the Tension Units menu The currently selected tension units such as lb kg or N are also displayed on the main tension screen e Perform...

Страница 8: ...ng stored data and can be adjusted to any setting b To retrieve or upload logged data from the instrument send a lower case d c Collected data will remain in memory regardless if instru ment is turned...

Страница 9: ...0 5 100 lb 0 5 lb 1 16 3 32 1 8 5 32 ACX 250 20 250 lb 0 5 lb 1 16 3 32 1 8 5 32 3 16 ACX 500 40 500 lb 1 0 lb 3 32 1 8 5 32 3 16 ACX CWT 20 250 lb 0 5 lb CWT 5 CWT 10 CWT 15 CWT 20 CWT 25 ACX CMB 20...

Страница 10: ...CWT 25 CWT Custom 9 Kilograms Decanewtons LBS Data Logging Optional Logging Duration Begin Logging View Data Setup Dampening Select 1 Hz 2 Hz 5 Hz Custom Names Resolution Select Custom 1 9 Re Calibrat...

Отзывы: