![Tense RGM-12S Скачать руководство пользователя страница 9](http://html1.mh-extra.com/html/tense/rgm-12s/rgm-12s_user-manual_1087694009.webp)
Measurement Screens
6
8 8 8 8
- 9 8 5
.
.
. .
8 8 8 8
3 5 0
.
. . .
8 8 8 8
2 3 0
.
. . .
Figure
φ
)
-1 (Cos
Figure-2 (Current (A))
Figure-3 (Voltage (V))
Figure-4 (F (Hz))
Figure-12 (PF)
8 8 8 8
5 0
.
. . .
8 8 8 8
7 9 2 9
.
. . .
8 8 8 8
1 3 8 9
.
. . .
8 8 8 8
8 0 5 0
.
. . .
8 8 8 8
5
.
. . .
8 8 8 8
8
.
. . .
8 8 8 8
1 3
.
. . .
8 8 8 8
2
.
. . .
8 8 8 8
0 8 5 0
.
.
. .
UP
DOWN
Figure-5 (P (kW))
Figure-11 (THD-I (%))
Figure-6 (Q (kVAr))
Figure-10 (THD-V (%))
Figure-7 (S (kVA))
Figure-8 (-Q/P (%Cap))
Figure-9 (Q/P (%Ind))
While on the measurement screen, the
"MEASUREMENTS" led on the device lights up.
While this LED is on, the values shown on the
screen are the values of the measurements. If you
move by pressing the down button while the
MEASUREMENTS led is on, the following
measurement values will be displayed
sequentially. Pressing the up button will display
the previous measurement parameter. While
showing these values, the led for the related
measurement value lights up.
Figure-1:
It shows the cosine value.
Figure-2:
It shows the current value.
Figure-3:
It shows the voltage value.
Figure-4:
It shows the frequency value.
Figure-5:
It shows the active power value.
Figure-6:
It shows the reactive power value.
Figure-7:
It shows the apparent power value.
Figure-8:
It shows the capacitive/active ratio (%)
value.
Figure-9:
It shows the inductive/active ratio (%)
value.
Figure-10:
It shows the THD-V (%) value.
Figure-11:
It shows the THD-I (%) value.
Figure-12:
It shows the power factor value.
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
7
8 8 8 8
- 9 8 5
.
.
. .
Figure-1
Setting Screen
8 8 8 8
2 5 0 0
.
.
. .
8 8 8 8
0 9 4 0
.
.
. .
8 8 8 8
2 0
.
. . .
8 8 8 8
0 0 1 0
.
.
. .
8 8 8 8
0 0 1 0
.
.
. .
8 8 8 8
1 0
.
. . .
8 8 8 8
3 0
.
. . .
8 8 8 8
2 5 0
.
. . .
8 8 8 8
- 9 8 5
.
. . .
Figure-13 (Pr.1)
Figure-14 (Pr.2)
Figure-15 (Pr.3)
8 8 8 8
1 0
.
. . .
Figure-16 (Pr.4)
Figure-24 (Pr.12)
8 8 8 8
3
.
. . .
Figure-17 (Pr.5)
Figure-23 (Pr.11)
8 8 8 8
3
.
. . .
Figure-18 (Pr.6)
Figure-22 (Pr.10)
Figure-19 (Pr.7)
Figure-20 (Pr.8)
Figure-21 (Pr.9)
In order to enter the setting screen, “SET”
button must be pressed for 2 seconds while in the
measurements screen. “SETTINGS” led on the
device lights up while on the setting screen. While
this LED is on, the values shown on the screen are
the values of the device settings. If you move by
pressing the down button while the SETTINGS led
is on, the values of the following setting
parameters will be displayed sequentially. While
showing these values, the led for the related
measurement value lights up. To change the value
of a parameter in the menu, enter the menu and
reach the relevant parameter with the help of up /
down buttons. Then press the SET button to enter
the relevant parameter, when you enter the
parameter, the led of the parameter will start to
blink. Then adjust the value you want with the up /
down buttons and press the SET button to save it.
The device will save the value and return to the
upper menu. After this process, the parameter led
will stop flashing and turn on steady.
Figure-13:
Pr1: Current Transformer Ratio
Figure-14:
Pr2: Step Values
Figure-15:
Pr3: Cosine Set Value
Figure-16:
Pr4: Cosine Tolerance Value
Figure-17:
Pr5: Step Drive Time (sec.)
Figure-18:
Pr6: Step Release Time (sec.)
Figure-19:
Pr7: Step Discharge Time (sec.)
Figure-20:
Pr8: Over Compensation Value
Figure-21:
Pr9: Under Compensation Value
Figure-22:
Pr10: THD-V Set Value (%)
Figure-23:
Pr11: THD-I Set Value (%)
Figure-24:
Pr12: High Voltage Set Value
8 8 8 8
1 0 0
.
.
. .
SET
The device shows the Cosine value on the measurements screen on the
left. While on any measurement screen, the SET button is pressed for 2
seconds in order to enter the menu.
(2sec.)
DOWN
UP
DOWN
UP
DOWN
UP
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
UP
DOWN
DOWN
UP