11. POSITIONING OF ELECTRODE PADS (cont)

Where only two pads are shown on the arm, shoulder, and leg, use 

the other two pads either on the opposite limb or place all four pads 

on the same limb in a square pattern with each pad being about 4 

inches apart. 

12. GENERAL PAD ADVICE

 

The electrode pads supplied are reusable but are for single  

 

patient use.

 

In order to obtain the best conductivity through the pads  

 

always ensure that they are in good condition and tacky.

 

Before use make sure your skin is clean and dry. 

 

Peel the electrode pads from their protective plastic shield by  

 

holding and lifting one corner of the pad and pulling. Do 

not

  

 

pull on the pigtail wire of the pad.

 

After use always replace the pads on the plastic liner and  

 

replace in the re-sealable plastic bag. 

 

If the pads dry out then it is best to buy a replacement pack

of electrodes. In an emergency it may be possible to restore 

some of the tackiness of the pad by adding a tiny drop of water 

on each pad and spreading around. If too much water is added 

the pads will become too soft then it is suggested in order to try 

re-establish some adhesiveness to place them sticky side up in a 

refrigerator for a few hours.

 

In very hot weather the gel on the pads may become soft. In  

 

such cases place the pads, still on their plastic liners and in  

 

their bag into a fridge until they return to their normal condition.

Содержание itouch easy

Страница 1: ...c t i o n s f o r U s e I N T E L L I G E N T T E N S TensCare Ltd 9 Blenheim Road Longmead Business Park Epsom Surrey KT19 9BE UK Tel 44 0 1372 723434 Email painaway tenscare co uk www tenscare co uk...

Страница 2: ...Screen Information 9 8 Contents 15 9 Installation of Batteries 15 10 Connecting Mono Lead wire 17 11 Positioning of Electrode Pads 18 12 General Pad Advice 20 13 Pad Alarm 22 14 The Belt Cradle 23 15...

Страница 3: ...th CSC you can increase the strength on the itouch easy in very small steps which is much more comfortable than conventional TENS units One Touch Memory Start The itouch easy has a memory which allows...

Страница 4: ...ificant reduction in pain if not complete pain relief 4 SIDE EFFECTS There are no known side effects to TENS use and long term TENS use is not harmful 5 THE PROGRAMMES There is no one programme approp...

Страница 5: ...sation Specific Uses E Constant This is similar to A but has Most types of acute deeper penetration and a and chronic pain stronger feel It is more including arthritis likely to produce muscle sciatic...

Страница 6: ...his enables the body to receive many different signals and can be very beneficial and lessen any effect of accommodation See programmes F and G Han Stimulation Professor Han in China found that altern...

Страница 7: ...ton Channel 2 Strength UP Channel 2 Strength DOWN Channel 1 Strength UP Time Selector Channel 2 Strength UP 7 SCREEN INFORMATION Programme selected Frequency selected Channel 1 strength selected Pulse...

Страница 8: ...to switch the unit off press and hold down this button for 3 seconds ON Channel 1 Strength UP button Note Channel 1 controls the output through the white leads To switch unit on Press and hold down fo...

Страница 9: ...press the Programme Selector button and release The programmes are shown as A B C D E F G or H Time Selector button Each time the unit is switched on it defaults back to continuous mode known as TIMER...

Страница 10: ...l Ensure that the batteries are inserted the right way as shown in battery compartment When the batteries are running low a low battery indicator will show on the screen battery symbol and it is impor...

Страница 11: ...the other end of the Mono Lead wire the lead wire splits into four pin ends 2 white and 2 black Push the pin ends into the pigtail ends of the electrode pads The mono lead wire can be split as requir...

Страница 12: ...rotective plastic shield by holding and lifting one corner of the pad and pulling Do not pull on the pigtail wire of the pad After use always replace the pads on the plastic liner and replace in the r...

Страница 13: ...contact between any of the pads and the skin or the quality of the pads is below the required standard the pad alarm will be triggered An audible bleep will be heard and at the top of the screen the...

Страница 14: ...ng solution than soap and water Clean the case and lead wires at least once a week by wiping with a damp cloth and a solution of mild soap and water Wipe dry 16 TROUBLESHOOTING Problem Possible causes...

Страница 15: ...S may affect seizure threshold During the first three months of pregnancy It is not known whether TENS may affect foetal development On the abdomen in the later stages of pregnancy Stop use immediatel...

Страница 16: ...brain are unknown Near malignant tumours In vitro experiments have shown that electricity can promote cell growth Do not Ignore any allergic reaction to the electrode pads If a skin irritation develo...

Страница 17: ...h 19 CONSUMABLES AND SERVICING Replacement electrode pads new batteries and lead wires are available from your supplier or distributor see back cover for contact details by mail order from TensCare by...

Страница 18: ...ked with a crossed out wheelie bin symbol as depicted below To comply with the Directive you can return your old electro therapy unit to us for disposal Simply print a postage paid PACKETPOST RETURNS...

Страница 19: ...ould be protected from liquids NB The electrical specifications are nominal and subject to variation from the listed values due to normal production tolerances EC Declaration of Conformity TensCare Lt...

Страница 20: ...5 UT 95 dip in Not applicable Not applicable interruptions and UT for 0 5 cycle voltage variations 40 UT 60 dip in on power supply UT for 5 cycles input lines 70 UT 30 dip in IEC 61000 4 11 UT for 25...

Страница 21: ...marked with the following symbol Rated maximum output power of transmitter W NOTE 1 At 80 MHz and 800 MHz the higher frequency range applies NOTE 2 These guidelines may not apply in all situations El...

Страница 22: ...39 NOTES...

Отзывы: