Tens EV-806P Скачать руководство пользователя страница 22

22

Telephone: 0800 121 4626                                                                              www.thetenscompany.co.uk 

The  TENS Programmes 
P01 - P12

NO      PROGRAMME                                                                                                                              FREQUENCY        PULSE WIDTH 

01 

    

Covential TENS

- Ideal for first applications of TENS                                    80Hz                    180µs

for both acute and long term pain

CONDITIONS 

Neck, Shoulder, Elbow Pain, Rheumatic Pain, Lumbago, Hip Pain,                    

Osteoarthritic Pain in the knee

02 

    

Burst TENS

- Most effective for radiating pain if arms                                  2Hz                      180µs

  and legs and deep muscular pain

          

CONDITIONS 

Osteoarthritic Pain in the Knee, Sciatica Central Pain                                         

03 

    

Modulated TENS

- Pain relief with a massage effect                                     80Hz                    70-180µs

          

CONDITIONS 

Neck, Shoulder, Elbow Pain, Rheumatic Pain, Lumbago,   

Menstrual Pain, Hip Pain, Osteoarthritic Pain in the knee

04 

    

Mixed Frequency TENS

                                                                                     15Hz/2Hz            180µs

          

CONDITIONS 

Osteoarthritic Pain in the knee, Neck Pain, Shoulder Pain, Menstrual Pain, 

Central Pain Lumbago                                                                                               

05 

    

Fixed Frequency TENS

- Effective programmes for long                             80Hz/2Hz            180µs

          term use with reduced accommodation factor
          

CONDITIONS 

Osteoarthritic Pain in the knee,   Neck Pain, Shoulder Pain Menstrual Pain, 

Central Pain Lumbago                                                                  

06 

    

Nausea

- Specifically for treatment of nausea, most                                     10Hz                    180µs

          successful placing electrodes over acupuncture point C6
          

CONDITIONS 

Nausea                                                                                                                          

07 

    

Migraine/Headaches

- Reduced pulse width ideal for                                   80Hz                    60µs

  

          treating nerve rich areas
          

CONDITIONS 

Tension Type Headache, Facial Pain, Neck Pain, Postherpetic Neuralgia

08 

    70% Rate Modulation over 10 seconds                                                              10Hz                    200µs

          

CONDITIONS 

Neck, Shoulder, Elbow Pain, Rheumatic Pain, Lumbago, Menstrual Pain, hip Pain,  

Osteoarthritic Pain in the Knee

09

     90% Rate Modulation over 10 seconds                                                              50Hz                    250µs

          

CONDITIONS 

Neck, Shoulder, Elbow Pain, Rheumatic Pain, Lumbago,     Menstrual Pain, hip Pain,

Osteoarthritic Pain in the Knee

10

     Mixed Frequency long term use programme. Ideal for                                  5-125Hz              120µs

          treating chronic pain over long periods  example 5+ hours                           
          

CONDITIONS 

Neck, Shoulder, Elbow Pain, Rheumatic Pain, Lumbago, Menstrual Pain, hip Pain,  

Osteoarthritic Pain in the Knee

11

     Modulation Rate & width over 6 seconds                                                         2-100Hz              260-150µs

          

CONDITIONS 

Neck, Shoulder, Elbow Pain, Rheumatic Pain, Lumbago, Menstrual Pain, hip Pain,

Osteoarthritic Pain in the Knee

12

     Modulation Rate over 6 seconds                                                                        80

<->7

Hz           260µs

          

CONDITIONS 

Neck, Shoulder, Elbow Pain, Rheumatic Pain, Lumbago,   Menstrual Pain, hip Pain,

Osteoarthritic Pain in the Knee                                                                               

Содержание EV-806P

Страница 1: ...ser Manual before using your Device Tel 0800 121 4626 www tensmachineuk com email sales thetenscompany co uk The Quick and Easy User Guide for the EV 806P TENS Neuromuscular Stimulator How to use the...

Страница 2: ...artel Court S Park Business Park Hamilton Road Stockport SK1 2AF Tel 0161 429 7330 Fax 0161 427 0215 Email sales thetenscompany co uk www tensmachineuk com Company registration number 08961942 Vat reg...

Страница 3: ...8 EMS INTRODUCTION 16 CAUTIONS 17 CONTRAINDICATIONS 18 ADVERSE REACTIONS 18 WARNINGS 19 SAFETY TECHNICAL CONTROLS 20 WHICH PROGRAMME SHOULD I USE 21 HOW HIGH SHOULD I TURN THE INTENSITY 21 THE PREMIER...

Страница 4: ...se 2 channel stimulator offers 24 medically researched pre set programmes P1 P12 are pre set TENS programmes P13 P12 are pre set muscle stimulator programmes STEP BY STEP GUIDE 4 Telephone 0800 121 46...

Страница 5: ...21 4626 Install the PP3 9V battery supplied into the compartment at the rear of the device This easy to use instruction manual explains how to set up the Med Fit EV 806P in programme mode STEP BY STEP...

Страница 6: ...shown in Fig B As already described the programmes P1 P12 are TENS programmes and P13 P24 are EMS programmes You are now ready to use your device It is recommended to now turn off the device and conne...

Страница 7: ...a necessary warning signal of trauma or malfunction in the body nature may have gone too far in its design Aside from its value in diagnosis long lasting persistent pain serves no useful purpose Pain...

Страница 8: ...both controls are in the off position the device is switched off By turning the controls clockwise the appropriate channel is switched on and the indicator of power CH1 or CH2 will reveal on the LCD T...

Страница 9: ...Increment Control This button controls the increase of settings When pressing this button the parameter will increase 6 Decrement Control This button controls the decrease of parameter When pressing t...

Страница 10: ...ressing the Mode control The mode you selected will show up on the top of liquid crystal display There are 5 modes of your option including B Burst M Normal M Modulation SD1 and SD2 When a TENS mode i...

Страница 11: ...or Decrement to adjust the setting Unless otherwise instructed turn the pulse rate control to the 70 120 Hz range e Set Timer The treatment time is adjustable from 1 to 60 minutes or C Continuous Pre...

Страница 12: ...s of option S Synchronous or A Alternate Select a mode by pressing the Mode control When an EMS mode is selected the LCD shows EMS on the top After a mode is selected press SET control to enter next s...

Страница 13: ...seconds to 90 seconds As the ON time including the ramp up and ramp down time the setting of it should be no less than two times of the Ramp time ON TIME Ramp up Ramp down j Set Off Time The Off Time...

Страница 14: ...70 120 us setting l Set Pulse Rate Pulse rate is adjustable from 2Hz to 150 Hz Press SET control to enter this menu then press Increment or Decrement to adjust the setting Unless otherwise instructed...

Страница 15: ...e power simultaneously The LCD will show the number of records and operation time Press the Increment and Decrement button to check each record To delete a record press SET control for 3 seconds Check...

Страница 16: ...by John Faraday in 1831 Through the square wave pattern it is able to work directly on muscle motor neurons The EMS has low frequency and this in conjunction with the square wave pattern allows direc...

Страница 17: ...Do not place electrodes on the front of the throat as spasm of the Laryngeal and Pharyngeal muscle may occur Stimulation over the carotid sinus neck region may close the airways make breathing diffic...

Страница 18: ...due to the electrical stimulation or electrical conductive medium The irritation can usually be reduced by using an alternate conductive medium or alternate electrode placement 6 Electrode placement a...

Страница 19: ...bitis thrombophlebitis varicose veins etc 7 Stimulation should not be applied over or in proximity to cancerous lesions MAINTENANCE TRANSPORTATION AND STORAGE OF THE DEVICE 1 Non flammable cleaning so...

Страница 20: ...arameters are set to the appropriate form of therapy Adjust the control correctly whether the cable is correctly connected to the device The cables should be inserted completely into the sockets wheth...

Страница 21: ...ou increase the intensity sensation feeling to the correct level Increase the intensity to a sensation which is comfortable and always perceptible never turn up to a level which is strong and uncomfor...

Страница 22: ...mbago 06 Nausea Specifically for treatment of nausea most 10Hz 180 s successful placing electrodes over acupuncture point C6 CONDITIONS Nausea 07 Migraine Headaches Reduced pulse width ideal for 80Hz...

Страница 23: ...ost suitable position for maximum pain relief If you are using two electrodes place the electrodes directly onto the painful area at a position where you feel the pain starts and where it finishes You...

Страница 24: ...mmes P8 P9 P10 P11 P12 Primary Placement Shoulder Pain Suggested Programmes P8 P9 P10 P11 P12 Primary Placement Alternative Placement Degenerative Arthritis Cervical and Lumbar Suggested Programmes P1...

Страница 25: ...n Suggested Programmes P8 P9 P10 P11 P12 Primary Placement Hip Neuralgia Suggested Programmes P1 P4 P11 P12 Primary Placement Phantom Limb Lower Extremity Suggested Programmes P8 P9 P10 P11 P12 Primar...

Страница 26: ...ment Alternative Placement Primary Placement Wrist Pain Suggested Programmes P9 Primary Placement Alternative Placement Carpal Tunnel Syndrome Suggested Programmes P9 Primary Placement Alternative Pla...

Страница 27: ...11 P12 Alternative Placement Primary Placement Knee Pain Post Op Suggested Programmes P2 P3 P4 P5 Primary Placement Alternative Placement Cervical Placement Suggested Programmes P1 P5 P12 Primary Plac...

Страница 28: ...OffTime Timer Hz s sec sec sec min 13 Muscle training Re education SYNCHRONOUS 30 300 0 1 1 30 14 Muscle training Re education SYNCHRONOUS 30 300 1 5 2 30 15 Muscle training Re education SYNCHRONOUS...

Страница 29: ...scle of the forearm Biceps Suggested Programmes P20 P24 This position is useful for muscle training and for gaining volume using the devices muscle strengthening programmes But it is equally very usef...

Страница 30: ...P15 P17 P20 P24 For you men this strengthening brings you more noticeable muscle build up for sports such as tennis or even football Internal Thigh Suggested Programmes P14 P15 P17 P20 P24 But for you...

Страница 31: ...d Dorsals Suggested Programmes P14 P15 P18 P20 P24 The Legs and Calves Suggested Programmes P15 P16 P18 P20 P24 The Abdominals Suggested Programmes P15 P16 P18 P20 P24 It is the abdominal muscle which...

Страница 32: ...e very difficult and painful to work on So go on the electrodes positioned like this will allow you to work on your muscles The Pectorals Suggested Programmes P14 P15 P19 P24 BE SURE to follow the pos...

Страница 33: ...from failure to follow the operating instructions accidents abuse alteration or disassembly by unauthorized personnel Manufacturer The Tens Company Ltd Unit 8 Martel Court S Park Business Park Hamilto...

Страница 34: ...urst Mode Burst rate Adjustable 0 5 5Hz Pulse width adjustable 50 300 s Frequency fixed 100 Hz 15 Normal Mode The pulse rate and pulse width are adjustable It generates continuous stimulation based on...

Страница 35: ...tting of ON Time should be no less than two times of the Ramp time in this mode ON TIME Ramp up Ramp down 20 Alternate Mode The stimulation of the CH2 will occur after the 1st contraction of CH1 is co...

Страница 36: ...Tel 0800 121 4626 Fax 0161 427 0215 www tensmachineuk com...

Отзывы: