TROUBLESHOOTING -- Continued
PROBLEM
CAUSE
SOLUTION
Little or no solution flow
(Conventional Scrubbing)
Clogged solution tank filter or solution
hose
Clean solution tank filter or flush out
solution hose
Clogged solution valve
Remove valve and clean
Solution flow control knob set too low
Adjust solution control flow knob
Loose screw on control knob
Calibrate knob and retighten screw
Poor water pickup
Recovery tank is full
Drain recovery tank
Loose drain hose cap
Tighten cap
Clogged float shut--off screen located
in recovery tank
Clean screen
Clogged squeegee assembly
Clean squeegee assembly
Worn squeegee blades
Replace or rotate squeegee blades
Incorrect Squeegee blade deflection
Adjust Squeegee blade height
Loose vacuum hose connections
Secure hose connections
Clogged vacuum hose
Remove clogged debris
Damaged vacuum hose
Replace vacuum hose
Recovery tank cover not in place
Properly position cover
Damaged recovery tank cover seal
Replace seal
Faulty vacuum motor
Contact Service Center
Low battery charge
Recharge batteries.
Short run time
Low battery charge
Fully recharge batteries
Defective batteries
Replace battery
Batteries need maintenance
See BATTERY MAINTENANCE
Faulty battery charger
Repair or replace battery charger
Brush pressure lever is set for extra
scrub head pressure
Lower brush pressure lever
ec--H2O
system indicator light
blinking red (
ec--H2O
Model)
Mineral deposit build--up in module
Flush module (See
ec--H2O
MODULE
FLUSH PROCEDURE)
Alarm sounds (
ec--H2O
Model)
ec--H2O
system indicator light sol-
id red (
ec--H2O
Model)
Defective module
Contact Service Center
ec--H2O
system indicator light
does not turn on (
ec--H2O
Model)
Defective light or module
Contact Service Center
No water flow (
ec--H2O
Model)
Clogged module
Contact Service Center
Defective solution pump
Contact Service Center