PLDC04453
REVISION 00
December 23, 2020
TECHNICAL OFFICE
Stavale
The drive relay is fitted to make the machine lighter to push, when the drive cannot
be used (no batteries, flat batteries or off).
When the machine is on, the dash board does not show any errors, the traction does not work
and the machine looks like with the wheels free, the problem could be the drive relay.
1
Move the machine onto flat and dry flooring.
2
Press the emergency switch fully in.
3
If possible, lift the machine by forklift.
4
The relay is fitted under the machine's chassis, at the rear, on the right, near the solenoid valve.
5
Disconnect the brown wire
A
and the black wire
B
and join them together, using a piece of wire.
6
Check if the relay is working correctly:
6a
If the machine moves, check if there is voltage (+24V) at the wires
C
and
D
.
6b
If the machine moves and there is voltage at the wires
C
and
D
, replace the relay.
6c
If the machine does not move, check if there is power supply to the motor or the motor carbon brushes.
1
If the relay works correctly, restore the connection, otherwise replace it.
Checking operation of the drive relay
Reassembly
C3 RELAY AND DRIVE MOTOR ELECTRICAL CONNECTIONS
C3.1 Checking and replacing the drive relay
*
WARNING
ONLY MACHINES WITH TRACTION MOTOR
Problem / Fault
A
B
+24 V
0 V
C
D
A
B
Fig. 123
57 of 73