Page 5 of 16
KIT NO. 9014091
9014108 Rev. 01 (11- 2017)
Tennant Company
www.tennantco.com
9. After machine is turned upright, continue routing the
ec-H2O pump solution hose as shown (Figure 21).
ec-H2O Pump
Solution Hose
Fig. 22
10. Using clamp [607775], connect hose fitting [20950] to
solution hose [376720] (Figure 23). Route the solution
hose towards the scrub head area following the same
path as the ec-H2O pump solution hose as shown in
Figure 22. The hose fitting end goes towards scrub
head area.
Solution Hose
[376720]
Solution Hose
[376720]
Clamp
[607775]
Fitting
[20950]
Fig. 23
PREPARE SCRUB HEAD:
1. Carefully turn scrub head over and install hose
support brackets at each motor hub location as shown
(Figure 24).
Hose Support
Bracket [1052298]
Washer
[01685]
Fig. 24
2. Cut the hose plug off from the manifold hose as
shown (Figure 25).
Cut
hose
plug
off
Fig. 25
3. Re-install the scrub head on machine with four pins
(Figure 25). Reconnect brush motor wire connectors,
solution hose connection, solution valve wires and
ground wire to scrub head.
Fig. 26
INSTALL ec-H2O MODULE ASSEMBLY:
1. Remove the two screws shown from machine frame to
mount ec-H2O module assembly (Figure 27).
Fig. 27