T12 Service Information 9009917 (12-12)
4-7
TROUbLESHOOTING
FAULT
CODE
FAULT MESSAGE
FAULT DESCRIPTION
SET/CLEAR
T12 LCD Fault Messages
F1
F2
F3
F4
F5
F6
F6
F2:SolTank Empty
F3:Vac#Flt#
F4:Batt Very Low
F5:Propel Error
F6:Left Br Flt#
F6:Frnt Br Flt#
F1:Rcv Tank Full
Solution Tank Empty
Over Current Vacuum Fan # (1 or 2) Motors,
Fault Type (1, 2, 3).
SET:
Fault #1 = Over Current for 15 Seconds;
Fault #2 = Current Exceeds 25A for 30 Seconds;
Fault #3 = Current Exceeds 35A for 2 Seconds.
CLEAR:
Cycle key switch.
SET:
Fault #1 = Current Exceeds 30A for 30 Seconds;
Fault #2 = Current Exceeds 40A for 5 Seconds;
Fault #3 = Over Current for 10 Seconds.
CLEAR:
Cycle key switch.
SET:
Fault #1 = Current Exceeds 30A for 30 Seconds;
Fault #2 = Current Exceeds 40A for 5 Seconds;
Fault #3 = Over Current for 10 Seconds.
CLEAR:
Cycle key switch.
SET:
Solution tank empty for 60 seconds
CLEAR:
Cycle key switch.
SET:
Battery discharge threshold of 30.2 Volts
at KSI terminal of PMC or 31.6 Volts at battery.
CLEAR:
Charge batteries to BDI reset threshold
of 37 Volts at KSI terminal of PMC or 38.3 Volts
at batteries.
SET:
Curtis 1232 PMC to T12 logic board
CAN-bus connectivity problem or
Curtis 1232 PMC power supply problem.
CLEAR:
See “Curtis 1232 Controller Diagnostics.”
SET:
Recovery tank full for 5 seconds.
CLEAR:
Recovery tank not full for 5 seconds.
Very Low Battery Voltage
Propel Controller CAN-bus Connectivity
Error
Left Brush Over Current, Fault #
Front Brush Over Current, Fault #
Recovery Tank Full
FMM001
Terms:
kSI = key Switch Interlock
pmC = propel motor Control
Содержание EC-H2O T12