MAINTENANCE
450 MM289 (1
−
92)
50
3. Lift up the solution tank to get access to the
batteries.
NOTE: The solution tank is easier to lift when it is
empty.
4. Check the water level in all the battery cells.
If the level is low, add just enough distilled
water to cover the plates. DO NOT
OVERFILL. The batteries can overflow
during charging due to expansion.
NOTE: Make sure the battery caps are in place
while charging.
FOR SAFETY: When Maintaining or Servicing
Machine, Avoid Contact With Battery Acid.
5. Unplug the machine connector from the
battery connector and plug the charger
connector into the battery connector.
WARNING: Batteries Emit Hydrogen
Gas. Explosion Or Fire Can Result.
Keep Sparks And Open Flame Away. Keep
Covers Open When Charging.
6. Plug the battery charger into the wall outlet.
NOTE: If the red “ABNORMAL CYCLE” lamp
lights when the optional TENNANT charger is
plugged into a wall outlet, the charger can not
charge the battery, there is something wrong with
the battery.
7. The optional TENNANT charger will start
automatically. When the batteries are fully
charged, the optional TENNANT charger will
automatically turn off.
07257
00879
07271
07224
Содержание 450
Страница 1: ...450 MM289 Rev 03 11 94 Operator Manual ...