MAINTENANCE
235E MM165 (3--94)
3-28
3. Place the vacuum lever in the “Normal
Sweeping”position.
4. Apply heat to the bottom of the Thermo
Sentry
t
with a match or lighter. The
vacuum lever should move to the “Wet
Sweeping”position, the hopper door should
close, and their circuit breakers should trip.
If they do not, the system is malfunctioning.
A
B
03393
THERMO SENTRY
t
A. Thermo Sentry
t
B. Shaker Motor
5. Replace the filter cover and check the
hopper cover seal. It should be slightly
compressed.
6. After the Thermo Sentry
t
has cooled,
reset the circuit breakers behind the control
panel.
HOPPER DUST FILTER
The hopper dust filter filters the air which is drawn
up from the main brush compartment by the
vacuum fan. It is located inside the dust filter
compartment. Shake the excess dust from the
filter daily. Inspect and clean or replace the dust
filter after every 100 hours of operation.
To clean the dust filter use one of the following
methods:
D
TAPPING -- Tap the filter gently on a
flat surface with the dirty side down. Do
not damage the edges of the filter
element or the filter will not seat
properly in the filter frame.
D
AIR -- Blow compressed air, 35 psi
(240 kPa) maximum, through the dust
filter opposite the direction of the
arrows. This may be done with the filter
in the machine. Always wear eye
protection when using compressed air.
FOR SAFETY: When Servicing Machine, Wear
Eye And Ear Protection When Using
Pressurized Air Or Water.
D
WATER -- Soak the dust filter in a water
and mild detergent solution. Rinse the
dust filter until it is clean. The maximum
water pressure allowable is 40 psi
(275 kPa). Air dry the wet filter; do not
use compressed air.
NOTE: Be sure the dust filter is dry before
reinstalling it in the machine.
Содержание 235E
Страница 1: ...235E MM165 Operator Manual ...
Страница 6: ...ABOUT THIS MANUAL 235E MM165 3 91 d ...
Страница 14: ...SPECIFICATIONS 235E MM165 3 91 1 2 ...
Страница 18: ...OPERATION 235E MM165 3 91 2 2 ...
Страница 34: ...MAINTENANCE 235E MM165 3 91 3 2 ...
Страница 42: ...MAINTENANCE 235E MM165 3 94 3 10 03380 HYDRAULIC SCHEMATIC ...
Страница 51: ...MAINTENANCE 3 19 235E MM165 3 93 03382 ELECTRICAL SCHEMATIC For machine below serial number 002205 ...
Страница 52: ...MAINTENANCE 235E MM165 3 93 3 20 03382 ELECTRICAL SCHEMATIC For machines from serial number 002205 to 002310 ...
Страница 53: ...MAINTENANCE 3 21 235E MM165 3 94 03382 ELECTRICAL SCHEMATIC For machines serial number 002311 and above ...
Страница 70: ...MAINTENANCE 235E MM165 3 94 3 38 ...
Страница 72: ...APPENDIX 235E MM165 3 91 4 2 ...