EN
CONTROL PANEL DISPLAY CODES:
Safety code
Cause
Actions to take
C22
Short circuit brush protection: stops all
functions
Reset by turning OFF the machine and starting again
C14
Dissipater at high temperature. Activates if
temperature is over 194° F
The machine resets when temperature lowers under 176° F
FS0
Worn brushes
Replace brush
SP1
Brush motor restricted
Inspect brush for obstruction.
Restart machine to reset
Yellow led lit
Battery in reserve
Machine continues to work.
Only a warning that the battery
is near discharge
Red led flashes
Battery discharged
Machine stops all functions
Turn off machine and charge
the battery
P1.X
Sweeping mode 1 button programming
activated
See programming
P2.X
Sweeping mode 2 button programming
activated
See programming
SF.X
Filter shaker program setting activated
See programming
X = A VALUE FROM “0” TO “5”