D. Testing for Continuity
(see figure 6)
To avoid damage to the Meter or to the devices
under test, disconnect circuit power and
discharge all the high-voltage capacitors before
measuring continuity.
To test for continuity, connect the Meter as follows:
Insert the red test lead into the
V Hz
terminal
and the black test lead into the
COM
terminal.
Set the rotary switch to
and press
SELECT
button to select measurement mode.
The buzzer sounds if the resistance of a circuit
under test is less than 30 .
The buzzer may or may not sound if the
resistance of a circuit under test is between 30
to 100 .
The buzzer does not sound if the resistance of
1.
2.
3.
4.
5.
Red
Black
Model 72-7228: OPERATING MANUAL
Warning
Figure 6