![Tenma 72-3540 Скачать руководство пользователя страница 7](http://html.mh-extra.com/html/tenma/72-3540/72-3540_manual_1086558007.webp)
7
ROTARY SWITCH
Switch Symbol
Function
Ṽ
Measurement of AC voltage
.
mṼ
Measuremnt of mV in AC and mV in AC+DC
.
V
Measurement of voltage in DC and AC+DC
.
mV °C °F
Measurement of mV in AC and temperature
.
ΩnS
Measurement of resistance, continuity and specific conductance
.
Diode test and capacitance measurement
.
Hz% mS-
Pulse Measurement of frequency, duty cycle and pulse width
.
µ
A
Measurement of µA in AC, DC and AC+DC
.
mA
Measurement of mA in AC, DC and AC+DC
.
A
Measurement of ampere in AC, DC and AC+DC
.
Battery charge
.
GENERAL SPECIFICATION
Max. voltage between any terminal
and ground
1000V
Fuse protection of mA or µA input
terminals
0.8A H 1000V fuse type 6 x 32mm
Fuse protection of A input terminals
10A H 1000V fuse type 10 x 38mm
Max. display
60000
Range
Auto/manual
Polarity
Auto
Operating temperature
-20°C~50°C
Storage temperature
-30°C~60°C
Relative humidity
≤80% (0°C~30°C), ≤75% (30°C~40C), ≤45%
(40°C~50C°)
Electromagnetic compatibility
In the RG-field of 1V/m: overall accuracy =
specified ac 5% of range.
No specified index for the RF-field over 1V/m.