www.element14.com
www.farnell.com
www.newark.com
www.cpc.co.uk
TM
TM
Page <5>
V1.0
12/03/19
Function
Range Accuracy
(% of r digits) Resolution
Frequency
400kHz ±(1.2% + 2d)
100Hz
10MHz ±(1.2% + 2d)
100Hz
Input sensitivity: 10mV rms
Over rang protection: 300V DC or 300V AC rms
Function
Range
Accuracy
(% of r digits) Resolution
Duty Cycle
0.1% ~ 99.9% ±1.2% of rdg ±2 dgts
0.1%
Sensitivity: <0.5V RMS
Pulsewidth:>100μs,<100ms;
Overload protection: 300V DC or 300V AC rms
Function
Range
Accuracy
(% of r digits) Resolution
Temperature
(-20.0°C to 760.0°C) ±(3.0% ± 5°C)
0.1°C
4°F to 1400°F)
±(3% ±8°F)
1°F
Sensor: K Type banana Play
Over rang protection: 250V DC or 250V AC rms
Function
Range
Accuracy
(% of r digits) Resolution
Capacitance
4nF
±(5% + 20d)
0.1nF
40nF
±(3.0% + 5d)
1nF
400nF
±(3.0% + 5d)
10nF
4μF
±(3.0% + 5d)
100nF
40μF
±(3.0% + 5d)
1μF
100μF
±(5.0% + 10d)
10μF
Over rang protection: 250V DC or 250V AC rms
5. General Specifications
Clampjawopening
1.2″(30mm)approx.
Display
3-3/4 digits (4000 counts) backlit LCD
Continuitycheck
Buzzersoundsatlessthan50Ω
Diode test
Test current of 0.5mA typical
Open circuit voltage
< 2V DC typical
Low Battery indication
‘ ’ is displayed
Over-range indication
‘OL’ display
Measurement rate
3 readings per second, nominal
Temperature sensor
Type K thermocouple
InputImpedance
10MΩ(VDCandVAC)
Operating Temperature
5°C to 40°C (41°F to 104°F)
Storage Temperature
-20°C to 60°C (-4°F to 140°F)