2
RUNNING MANUAL
TenarisHydril
CONNECTION SPECIFIC RUNNING GUIDELINES
T
enarisHydril EasyDock™ Connection
Equipment, Material & Documents
1.
Verify the appropriate thread compound is available
onboard for this connector.
2.
Refer to document FTD29356 “Premium Connection
Approved Thread Compounds” for a list of compounds
approved by Tenaris.
3.
Latest version of the specific Product Data Sheet
can be obtained from Tenaris web site. In case it is not
available, request the data sheet to the local Technical
Sales representative or
4.
Verify the compatibility of the EasyDock™ connector
with accessories such as pup joints, etc.
5.
Ensure accessories such as O-rings, spare Anti
Rotation Keys (ARK’s) and ARK installation tools are
available on the rig prior to operation commencement.
6.
Specific tools required for successful running or
pulling of EasyDock™
.
Allen key: 5 mm
.
Spare ARKs and hexagonal bolts
.
Hammer
.
Chisel
Pre-Running
1.
Check weld cord, ensuring the elevators can pass
over to seat against the connector.
2.
The following connector information will be hard-
stamped on the connector OD.
.
Connector name
.
OD
.
Connector SMYS